ACCIDENT PREVENTION REQUIREMENTS

6.
The boiler is a zone of increased hazard. If behaving irresponsibly, it is possible to get hurt,
poisoned, make a fire, spoil the boiler or heating system.
SAFETY REQUIREMENTS AND
PROHIBITIONS
Do not boil water in the boiler
Do not kindle the boiler without water. Do not exceed
pressure in a system over 1.5 bars. Do not freeze water
in the heating system and boiler.
Air from outside must get into a boiler
Do not pass the air through a lower
door and do not load firewood logs
through the under part
Do not store fuel in the boiler (after
loading firewood logs must be ignited)
Do not move the air distributor during
combustion
MOST FREQUENT FITTING MISTAKES
It is fitted according to the diagrams of
other boiler manufacturers where it is
provided the return of a big amount of
heated water to a reversionary flow as if it
removes a negative effect of the condensate
Circular pump together with the boiler
is fitted in the old system where elements
are not regulated
room
CONSEQUENCES IF NOT FOLLOWING
PROHIBITIONS AND MEASURES
If water boils away, the boiler will overheat and will
crack. If the boiler boiled up due to a reason which is
not known to you, keeping the face away from doors,
open them and pour water into a firebox.
Spoilage of boiler and other heating
It is possible to get poisoned besides the boiler does
not operate – open a window in a boiler room or inject
the air into a boiler room otherwise.
Condensate shall leak; more firewood logs will be
consumed. Water will boil up in the boiler, coal will
Fire wood will burn up from the remaining ember and
will fume useless leaving the condensate and tars.
While stabbing the air distributor softened from heat
on to the firewood logs, it will become folded and if
sinked deeper into fuel - will get worn from heat more
CONSEQUENCES/ REMOVAL
Intense flow sufficiently cools combustion
compartments and smoke crack walls so
that moister shall be discharged on them
though it is dried while heating but glues
ash onto the walls therefore the boiler and
chimney flue periodically clog.
Set a recommended flow – moister shall
accumulate below a combustion fireplace –smoke
cracks will be always clean.
Due to an intense flow of cool water a lot
of condensate is discharged, a poisoned
smell of condensate gets into a boiler room
and the boiler running is such uneconomical
that it lacks its capacity.
Mount a balance tap in front of the boiler
or mount in a boiler.
21
system parts
drop down.
rapidly.