Ceiling Concealed Duct
Indoor unit type
Power Supply
Cooling Capacity
Heating Capacity
Current
Nominal running current
Fan
Motor Type
Fan Type
Motor Output x Number of Unit
Air Flow Rate(H/M/L)
External Static Pressure
Capacitor
Drive
Coil
Row x Columns x FPI
Dimensions(WxHxD) Body
Weight
Body
Air Filter
Sound Level (H/M/L)
Piping
Liquid
Connections
Gas
Drain(OD/ID)
Dehumidification Rate
Safety devices
Temperature Sensor
Referigerant
Referigerant Control
Connectable outdoor unit
Power and transmission interunit cable
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. Cooling/heating capacity of indoor unit can be lower when it is connected to MPS variable outdoor.
3. Wiring cable size must comply with the applicable local and national code.
50 Universal System Air Conditioner
Model
Ø/V/Hz
kW
Btu/h
kW
Btu/h
A
cmm
cfm
mmAq
µF/Vac
mm
mm(inch)
kg(lbs)
dB(A)+3
mm(inch)
mm(inch)
mm
l/h
No.x mm
Ceilling Concealed Duct - High Static
ABNH366GLAB
[UB36 NGB]
1 / 220 ~240 / 50
10.6
36,000
12.1
41,400
1.42
Induction
Sirocco Fan
272*2
32/29/26
1130/1024/918
10
6/370
Direct Drive
3R x 10C x 21
1180*298*450(46.5*11.7*17.7) 1230*380*590(48.4*15.0*23.2) 1230*380*590(48.4*15.0*23.2)
38(84)
Long life filter
42/39/36
6.35 (1/4)
15.88(5/8)
32/25
4.0
Fuse, Thermal protector for fan motor Fuse, Thermal protector for fan motor Fuse, Thermal protector for fan motor
Thermistor
R-410A
LEV
Single A
2
4*0.75
ABNH486RLAB
ABNH606RLAB
[UB48 NRB]
[UB60 NRB]
1 / 220 ~240 / 50
1 / 220 ~240 / 50
14.1
48,000
15.5
52,800
3.65
Induction
Induction
Sirocco Fan
Sirocco Fan
431*2
40/35/30
50/45/40
1413/1236/1059
1766/1413/1236
15
15/450
Direct Drive
Direct Drive
3R x 13C x 19
4R x 13C x 19
60(132)
Long life filter
Long life filter
44/42/40
46/44/42
9.52(3/8)
9.52(3/8)
19.05(3/4)
19.05(3/4)
32/25
6.0
Thermistor
Thermistor
R-410A
LEV
Single A
Single A
4*0.75
Conversion Formula
= Btu/h × 0.0002931
kW
kcal/h = Btu/h × 0.252
CFM = CMM × 35.3
16.4
56,000
18.1
61,600
3.65
431*2
15
15/450
60(132)
32/25
6.5
R-410A
LEV
4*0.75

Hide quick links: