12) Troubleshooting CH51, CH60
Display
Title
code
51
Over capacity
EEPROM
60
Check sum
Model
AUUW126B
AUUW186B
AUUW246B
AUUW306B
AUUW366B
AUUW4860
AUUW6060
Check Point
• CH 51
1. Check the indoor unit capacity.
Cause of error
• Over capacity
Combination
• Check sum error
Gross max. capacity
21k
24k
33k
39k
52k
Check point & Normal condition
• Check the indoor unit capacity.
• Check the combination table.
• Check the PCB ASM P/No.
• Check the poor soldering.
Max. single indoor unit capacity
12k
12K
18K
18K
24K
• CH 60
1. Check the insertion condition of EEPROM.
2. Check the poor soldering
Troubleshooting Guide