Minimum Clearance To Combustibles - Napoleon BGD42CFN Installation And Operating Instructions Manual

Natural & propane gas
Table of Contents

Advertisement

26
49"
MINIMUM
ENCLOSURE
HEIGHT
5.1

MINIMUM CLEARANCE TO COMBUSTIBLES

Minimum clearance to combustible construction from appliance and vent surfaces:
Combustible framing:
Sides, back, bottom and top of the appliance
Non-combustible  nishing:
Top
Combustible framing:
Sides and bottom
Enclosure top
Recessed depth
Top, sides and bottom of vent pipe
Ceiling
W415-0779 / D / 08.13.12
NOTE: Do not build into this area - it must be left clear to provide
adequate clearance for the vent in this 14" wide area centered
along the front of the fireplace. No combustibles are allowed.
1 1/2" MAX
14" MIN
1 1/2"
MAX
25 1/4"
41 3/4"
46 1/2"
0" to standoffs
6 1/2" to appliance edge
0" to appliance edge
13 1/2" to top of appliance
25"
2"
54" from bottom of appliance