Microwave Leakage Testing

!
WARNING
Check for radiation leakage after servicing. Should the
leakage be more than 4mW/cm
Refrigeration, Inc. immediately. After repairing or
replacing any radiation safety device, keep a written
record for future reference, as required by D.H.H.S.
and HEW regulations. This requirement must be
strictly observed. In addition, the leakage reading
must be recorded on the service repair ticket while in
the customer's home.

Equipment

• Electromagnetic radiation monitor
• 600 cc glass beaker
Procedure For Measuring Radiation
Leakage
Note before measuring -
• Do not exceed meter full scale deflection. Leak
monitor should initially be set to the highest scale.
• To prevent false readings the test probe should be
held by the grip portion of the handle only.
• The scan speed is equal to one inch per antenna
revolution or one inch per second if antenna speed is
unknown.
• Areas to be checked are all door seal areas and any
venting parts.
• Leakage with the outer panel removed...4mW/cm
less.
• Leakage for fully assembled oven with door normally
2
closed ...4mW/cm
or less.
• Leakage for a fully assembly oven (before the latch
switch (primary) is interrupted) while pulling the door ...
2
4mW/cm
or less.
1 . Pour 275 ± 15 cc (9 oz ± 1/2 oz) of 20 ± 5°C. (68±
9°F.) water in a beaker which is graduated to 600 cc
and place the beaker in the center of oven.
2. Set the radiation monitor to 2450 MHz and use it
following the manufacturer's recommended test
procedure to assure correct results.
3. While measuring the leakage, always use the two
inch (5 cm) spacer supplied with the probe.
4. Press the START pad or turn on the timer and with
the magnetron oscillating, measure the leakage by
holding the probe perpendicular to the surface being
measured.
RS2220001 Rev. 2
2
inform Amana
2
or
6
Measurement With the Outer Panel
Removed
!
DANGER
Avoid contacting any high voltage components.
Whenever you replace the magnetron, measure for
radiation leakage before the outer panel is installed and
after all necessary components are replaced or
adjusted. Special care should be taken in measuring
around the magnetron.

Measurement With a Fully Assembled Oven

After all components, including the outer panel are fully
assembled, measure for radiation leakage around the
door periphery, the door viewing window, the exhaust
opening, and air inlet openings.
Record Keeping and Notification After
Measurement
1. After any adjustment or repair to a microwave oven,
a leakage reading must be taken. Record this
leakage reading on the repair ticket even if it is zero.
2. A copy of the repair ticket and the microwave
leakage reading should be kept by the repair facility.