Sony CFD-G30 Service Manual page 10

Table of Contents

Advertisement

TUNER SECTION
• Switch Location
VOLUME
MEGA BASS
PRESET SOUND MODE : OFF
AM SECTION
BAND : AM
Signal generator
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
FM SECTION
BAND : FM
Signal generator
FM RF signal
generator
75kHz (100%) amplitude modulation
by 1kHz signal.
Output level : as low as possible
set
0 dB = 1 µV
: MAX
: OFF
Put the lead-wire
antenna close to
the set.
0.01 µ F
telescopic
antenna
terminal
level meter
32 Ω
+
J391 (phones)
• Repeat the procedures in each adjustment several times for the
maximum level meter indication.
• The frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
Adjust for a maximum reading on level meter.
T2
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
Adjust for a maximum reading on level meter.
T1
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
[Adjustment Location : Main board] (Component side)
L4
AM F-COVER.
Adjustment
CT3
AM TRACKING
Adjustment
— 10 —
AM IF ADJUSTMENT
455 kHz
620 kHz
1,400 kHz
520 kHz
FM IF ADJUSTMENT
10.7 MHz
86.5 MHz
109.5 MHz
86.5 MHz
L2
FM F-COVER.
Adjustment
L3
CT1
L1
FM TRACKING
Adjustment
T2
AM IF
Adjustment
T1
FM IF
Adjustment