*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size.
NOTE − Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length calculation.
Number Of
90° Elbows
Used
070
1
91
2
86
3
81
4
76
5
71
6
66
7
61
8
56
9
51
10
46
Number Of
90° Elbows
Used
070
1
66
2
61
3
56
4
51
5
46
6
41
7
36
8
31
9
26
10
21
Number Of
90° Ebows
Used
070
1
83
2
78
3
73
4
68
5
63
6
58
7
53
8
48
9
43
10
38
Number Of
90° Elbows
Used
070
1
58
2
53
3
48
4
43
5
38
6
33
7
28
8
23
9
18
10
13
Maximum Allowable Intake or Exhaust Vent Length in Feet
Standard Termination at Elevation 0 − 7500'
2" Pipe
Model
090
110
135
69
14
64
9
59
54
49
n/a
44
n/a
39
34
29
24
Standard Termination at Elevation 7501' − 10,000'
2" Pipe
Model
090
110
135
44
39
34
29
24
n/a
n/a
19
14
n/a
Concentric Termination at Elevation 0 − 7500'
2" Pipe
Mode
090
110
135
67
12
62
7
57
52
47
n/a
42
n/a
37
32
27
22
Concentric Termination at Elevation 7501' − 10,000'