[3] Precautions for installing the thin coax-
ial
Attach the connector cover before installing the thin coaxial.
After the installation, leave the connector cover off.
Part Code
PCOVPA003AFZZ
Cover, Connector
Fit the hooks of the
hinge holder.
Hole B
Hinge Unit
Blue
Wire Holder B
CONFIDENTIAL
Description
Fix Holder, Hinge
Fit the hooks of the
hinge holder.
Hinge Unit
The thin coaxial connector
should be routed through the
wire holders A and B
beforehand.
Yellow
Wire Holder A
Cover,
Connector
Sagging must be
out of the hole B.
Hinge Unit
Thin Coaxial
(Earth FPC)
Thin Coaxial
(Cable)
Position the thin coaxial
(earth FPC) outside the
thin coaxial (cable). Pay
special attention to the
sections "a" and "b".
Adjusting the length, insert the
thin coaxial into the hinge holder.
The earth FPC must
be in contact with the
hinge unit.
End face
Nitoflon
of the
overlap
earth
area
FPC
Holder, Hinge
Wiring location:
Align the end face of
the flexible PWB with
the inner surface of
the hinge unit fitting.
The end face of the earth FPC
must be within this range.
(Keep it inside the hinge.)
3 – 6
When routing through the hole
B, straighten the thin coaxial and
continue to make arcs with it.
Hole A
Hole B
A
a
b
Fix the "A" part and bend the
thin coaxial into an N shape to
insert the hole A. This prevents
twisting of the thin coaxial (ca-
ble/earth FPC).
Thin Coaxial
Hinge Unit
Earth FPC