Alternate Power Supplies; Electrical Data; V Wiring - Carrier 59SC2C Series Installation, Start-Up, Operating And Service And Maintenance Instructions

Single stage 4-way multipoise condensing gas furnace series 1
Table of Contents

Advertisement

6. Attach furnace J- -Box cover to mounting bracket with
screws supplied in loose parts bag. Do not pinch wires
between cover and bracket.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous
operation, personal injury, death, or property damage.
Do not drill into blower shelf of furnace to route control
wiring. Route any control or accessory wiring to the blower
compartment through external knockouts on the casing.

24- -V Wiring

Make field 24- -v connections at the 24- -v terminal strip. See Fig.
38. Connect terminal Y as shown in Fig. 37 for proper cooling
operation. Use only AWG No. 18, color- -coded, copper thermostat
wire.
NOTE: Use AWG No. 18 color-coded copper thermostat wire for
lengths up to 100 ft. (30 M). For wire lengths over 100 ft., use
AWG No. 16 wire.
The 24- -v circuit contains an automotive- -type, 3- -amp. fuse located
on the control. Any direct shorts during installation, service, or
maintenance could cause this fuse to blow. If fuse replacement is
required, use ONLY a 3- -amp. fuse of identical size. See Fig. 38.
Accessories
(See Fig. 36 and 38.)
1. Electronic Air Cleaner (EAC)
Connect an accessory Electronic Air Cleaner (if used) using
VOLTS---
HERTZ---
UNIT SIZE
PHASE
040--- 10
115--- 60--- 1
040--- 12
115--- 60--- 1
060--- 12
115--- 60--- 1
060--- 16
115--- 60--- 1
080--- 16
115--- 60--- 1
080--- 20
115--- 60--- 1
100--- 16
115--- 60--- 1
100--- 20
115--- 60--- 1
120--- 20
115--- 60--- 1
* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier,
etc.) full load amps.
Time ---delay type is recommended.
{
Length shown is as measured one way along wire path between furnace and service panel for maximum 2 percent voltage drop.
}
Table 12 – Electrical Data
OPERATING VOLTAGE
MAXIMUM
RANGE*
UNIT
AMPS
Maximum*
Minimum*
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
11.9
127
104
11.9
1/4- -in. female quick connect terminals to the two male
1/4- -in. quick- -connect terminals on the control board
marked EAC- -1 and EAC- -2. The terminals are rated for
115VAC, 1.0 amps maximum and are energized during
blower motor operation.
2. Humidifier (HUM)
The HUM terminal is a 24 VAC output, energized when the LPS
closes during a call for heat.
Connect an accessory 24 VAC, 0.5 amp. maximum humidifier (if
used) to the ¼- -in. male quick- -connect HUM terminal and
COM- -24V screw terminal on the control board thermostat strip.
NOTE: If the humidifier has its own 24 VAC power supply, an
isolation relay may be required. Connect the 24 VAC coil of the
isolation relay to the HUM and COM/24V screw terminal on the
control board thermostat strip. See Fig. 36.

Alternate Power Supplies

This furnace is designed to operate on utility generated power
which has a smooth sinusoidal waveform. If the furnace is to be
operated on a generator or other alternate power supply, the
alternate power supply must produce a smooth sinusoidal
waveform for compatibility with the furnace electronics. The
alternate power supply must generate the same voltage, phase, and
frequency (Hz) as shown in Table 12 or the furnace rating plate.
Power from an alternate power supply that is non-sinusoidal may
damage the furnace electronics or cause erratic operation.
Contact the alternate power supply manufacturer for specifications
and details.
MINIMUM
UNIT
AMPACITY#
5.2
7.5
7.4
10.3
5.3
7.6
8.6
11.7
8.1
11.1
8.6
11.7
7.3
10.1
15.8
15.8
37
MAXIMUM
MAXIMUM
WIRE
WIRE
FUSE OR CKT
SIZE
LENGTH
BKR
AWG
FT (M)}
AMPS{
14
49 (14.9)
14
36 (11.0)
14
48 (14.6)
14
31 (9.4)
14
33 (10.1)
14
31 (9.4)
14
36 (11.0)
12
36 (11.0)
12
36 (11.0)
15
15
15
15
15
15
15
20
20

Advertisement