SPLIT SYSTEM HEATING PERFORMANCE
MODEL: SSZ160601B* CAPF4961D6 MBVC2000A - LOW STAGE
65
60
55
MBh
49.9
47.3
44.5
T/R
40.2
38.1
35.8
KW
3.51
3.44
3.36
AMPS
18.3
16.9
15.9
COP
4.17
4.03
3.87
EER
14.2
13.8
13.2
MODEL: SSZ160601B* CAPF4961D6 MBVC2000A - HIGH STAGE
65
60
55
MBh
71.0
67.2
63.3
T/R
37.6
35.6
33.5
KW
4.67
4.58
4.49
AMPS
22.9
21.2
19.9
COP
4.45
4.30
4.13
EER
15.2
14.7
14.1
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature
Pressures show n are for most popular match indoor unit WITH NO FROST ON OUTDOOR COIL. Due to factors like airflow , charge, indoor coil & frost, pressures w ill vary
significantly. Liquid (small) service valve pressures should be ± 20 psig & suction (access port) pressures should be ±5 psig of the values listed in this chart.
Indoor Return
Indoor
Air Dry Bulb
Air Flow
T emperature
Rate
(ºF)
Liq
65
276
1050
70
296
75
317
65
266
1200
70
286
75
307
65
260
1350
70
279
75
299
65
283
1580
70
304
75
326
65
274
1800
70
294
75
315
65
267
2030
70
287
75
307
24
EXPANDED PERFORMANCE DATA
Outdoor Ambient Temperature
50
47
45
40
41.6
39.7
38.5
35.8
33.5
32.0
31.0
28.8
3.29
3.25
3.22
3.15
14.9
14.4
14.1
13.3
3.70
3.58
3.50
3.32
12.6
12.2
12.0
11.4
EXPANDED PERFORMANCE DATA
Outdoor Ambient Temperature
50
47
45
40
59.2
56.5
54.7
50.9
31.3
29.9
29.0
26.9
4.40
4.34
4.30
4.22
18.7
18.0
17.7
16.6
3.94
3.81
3.72
3.53
13.5
13.0
12.7
12.1
HEATING MODE PRESSURE CHART
17
22
27
Suct
Liq
Suct
Liq
Suct
Liq
56
284
65
293
73
301
56
305
65
313
73
322
56
326
64
335
73
344
56
275
64
283
73
291
56
294
65
303
73
311
56
315
65
324
74
332
56
268
64
276
73
284
56
287
64
295
73
303
56
307
65
316
73
324
56
290
63
296
70
302
55
310
63
317
70
323
55
332
63
338
70
344
55
280
62
286
70
292
56
300
63
306
70
312
56
321
63
327
70
333
55
273
62
279
70
284
55
292
63
298
70
304
56
313
63
319
70
324
35
30
25
20
33.0
30.8
28.4
26.2
26.5
24.8
22.9
21.1
3.08
3.47
3.38
3.30
12.7
12.1
11.6
11.1
3.14
2.60
2.46
2.32
10.7
8.9
8.4
7.9
35
30
25
20
46.9
44.6
41.2
37.9
24.8
23.6
21.8
20.1
4.12
4.62
4.51
4.41
15.8
15.1
14.4
13.7
3.33
2.82
2.67
2.52
11.4
9.6
9.1
8.6
Outdoor Air Dry Bulb Tem perature (ºF)
32
37
42
Liquid Valve & Compre ssor Suction Pressure
Suct
Liq
Suct
Liq
Suct
Liq
82
310
91
319
99
328 108 336 116 345 125 354 134 363 142
82
331
90
339
99
348 107 357 116 365 125 374 133 383 142
81
352
90
361
99
370 107 378 116 387 124 395 133 404 141
81
300
90
308
98
316 107 325 115 333 124 342 132 350 141
82
320
90
328
99
336 107 345 116 353 124 361 133 370 141
82
340
91
349
99
357 108 365 116 374 125 382 133 390 142
81
292
90
300
98
309 107 317 115 325 124 333 132 342 141
82
312
90
320
99
328 107 336 116 344 124 352 133 361 141
82
332
91
340
99
348 108 356 116 364 125 372 133 380 142
78
308
85
314
92
321 100 327 107 333 114 340 122 346 129
77
329
85
335
92
341
77
350
84
356
92
362
77
298
84
304
91
310
77
318
85
323
92
329
78
338
85
344
92
350 100 355 107 361 114 367 121 372 129
77
290
84
296
91
302
77
310
84
315
92
321
78
330
85
335
92
341
SSZ160601B*
HEATING OPERATION
17
15
10
5
24.7
23.8
21.3
18.9
19.9
19.2
17.2
15.2
3.25
3.22
3.13
3.05
10.8
10.7
10.1
9.5
2.22
2.16
2.00
1.82
7.6
7.4
6.8
6.2
HEATING OPERATION
17
15
10
5
35.8
34.5
30.9
27.4
18.9
18.2
16.4
14.5
4.34
4.30
4.19
4.08
13.4
13.2
12.6
11.7
2.41
2.35
2.16
1.97
8.2
8.0
7.4
6.7
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
47
52
57
Suct
Liq
Suct
Liq
Suct
99
347 107 353 114 359 121 365 129
99
368 106 374 114 380 121 385 128
99
316 106 322 113 328 121 334 128
99
335 106 341 114 347 121 353 128
99
308 106 314 113 320 120 326 128
99
327 106 333 114 338 121 344 128
99
347 107 352 114 358 121 363 129
Label p/n: 0140R00181-A
-5
-10
16.5
14.1
11.5
13.3
11.3
9.3
2.96
2.88
2.79
8.9
8.3
7.5
1.63
1.43
1.21
5.6
4.9
4.1
-5
-10
23.9
20.4
16.7
12.7
10.8
8.8
3.98
3.87
3.76
11.0
10.2
9.2
1.76
1.54
1.30
6.0
5.3
4.4
62
67
Liq
Suct
Liq
Suct

Hide quick links: