SPLIT SYSTEM HEATING PERFORMANCE
MODEL: SSZ160241A* / CA*F3636*6A* + TXV / MBE1600**-1
65
60
55
MBh
30.2
28.6
26.9
Delta T
31.9
30.2
28.4
KW
1.79
1.75
1.72
AMPS
8.4
7.8
7.3
COP
4.93
4.76
4.57
EER
16.9
16.3
15.6
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature
Pressures show n are for most popular match indoor unit WITH NO FROST ON OUTDOOR COIL. Due to factors like airflow , charge, indoor coil & f rost, pressures w ill vary
significantly. Liquid (small) service valve pressures should be ± 20 psig & suction (access port) pressures should be ±5 psig of the values listed in this chart.
Indoor Return
Indoor
Air Dry Bulb
Air Flow
T emperature
Rate
(ºF)
Liq
65
266
740
70
286
75
306
65
257
850
70
276
75
296
65
251
960
269
70
75
289
20
EXPANDED PERFORMANCE DATA
Outdoor Ambient Temperature
50
47
45
40
25.1
24.0
23.3
21.6
26.6
25.4
24.6
22.9
1.66
1.68
1.65
1.62
6.9
6.7
6.6
6.2
4.37
4.22
4.13
3.91
14.9
14.4
14.1
13.4
HEATING MODE PRESSURE CHART
17
22
27
Suct
Liq
Suct
Liq
Suct
Liq
64
277
72
288
79
298
64
297
71
308
79
319
64
318
71
329
79
340
63
267
71
278
79
288
64
287
71
297
79
308
64
307
72
318
79
329
63
261
71
271
78
281
64
280
71
290
79
300
64
299
72
310
79
320
35
30
25
20
19.9
18.7
17.3
15.9
21.1
19.8
18.3
16.8
1.58
1.68
1.64
1.60
5.9
5.7
5.4
5.2
3.69
3.26
3.08
2.91
12.6
11.2
10.5
9.9
Outdoor Air Dry Bulb Temperature (ºF)
32
37
42
Liquid Valve & Compressor Suction Pressure
Suct
Liq
Suct
Liq
Suct
Liq
87
309
95
320 102 331 110 342 118 353 125 364 133 375 141
87
330
94
341 102 351 110 362 117 373 125 384 133 395 140
86
351
94
362 102 373 109 384 117 395 125 406 132 417 140
86
299
94
309 101 320 109 330 117 341 124 351 132 362 140
87
318
94
329 102 340 110 350 117 361 125 371 132 382 140
87
339
95
350 102 361 110 371 118 382 125 392 133 403 141
86
291
94
301 101 312 109 322 117 332 124 342 132 353 140
87
311
94
321 102 331 109 341 117 352 125 362 132 372 140
87
331
95
341 102 352 110 362 118 372 125 383 133 393 140
SSZ160241A*
HEATING OPERATION
17
15
10
5
15.0
14.4
13.0
11.5
15.9
15.3
13.7
12.2
1.58
1.56
1.52
1.48
5.1
5.0
4.7
4.4
2.79
2.71
2.49
2.27
9.5
9.3
8.5
7.7
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
47
52
57
Suct
Liq
Suct
Liq
Suct
Liq
Label p/n: 0140R00187-A
0
-5
-10
10.0
8.6
7.0
10.6
9.0
7.4
1.45
1.41
1.37
4.2
3.9
3.5
2.03
1.78
1.50
6.9
6.1
5.1
62
67
Suct
Liq
Suct

Hide quick links:

Advertisement

loading