Goodman SSZ 16 SEER Technical Manual

Goodman SSZ 16 SEER Technical Manual

Ssz 16 seer split system heat pumps
Hide thumbs Also See for SSZ 16 SEER:

Advertisement

Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
Copyright © 2006-2007, 2009-2010, 2012, 2014
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
SSZ 16 SEER
Split System Heat Pumps
Goodman Manufacturing Company, L.P.
AL
AL
AL
AL
RT6214002r10
February 2014

Advertisement

loading

Summary of Contents for Goodman SSZ 16 SEER

  • Page 1 Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does RT6214002r10 not assume any responsibility for property damage or personal injury due to improper service February 2014 procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Installation and repair of this unit Goodman will not be responsible WARNING WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    PRODUCT DESIGN SSZ16 models are available in 2, 3, 4 and 5 ton sizes and These clearances will help avoid air recirculation. If installing two or more units at the same location, allow at least 24 use R-410A refrigerant. They are designed for 208/230 volt inches between units.
  • Page 5 HEAT PUMP SPECIFICATIONS SSZ160241A* - SSZ160601A* Cooling Capacity, BTUH 24,000 36,000 48,000 60,000 Compressor R.L. Amps 13.5 14.1 19.9 25.6 L.R. Amps 58.3 77.0 109.0 118.0 Low Pressure Switch Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG...
  • Page 6 HEAT PUMP SPECIFICATIONS SSZ160601B* Cooling Capacity, BTUH 60,000 60,000 Compressor R.L. Amps 23.0 28.8 L.R. Amps 118.0 152.9 Low Pressure Switch Open 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG High Pressure Switch Open 610 PSIG 610 PSIG Close 420 PSIG 420 PSIG Condenser Fan Motor...
  • Page 7 COOLING PERFORMANCE DATA SSZ160241A*...
  • Page 8 COOLING PERFORMANCE DATA SSZ160241A*...
  • Page 9 COOLING PERFORMANCE DATA SSZ160361A*...
  • Page 10 COOLING PERFORMANCE DATA SSZ160361A*...
  • Page 11 COOLING PERFORMANCE DATA SSZ160481A*...
  • Page 12 COOLING PERFORMANCE DATA SSZ160481A*...
  • Page 13 COOLING PERFORMANCE DATA SSZ160601A*...
  • Page 14 COOLING PERFORMANCE DATA SSZ160601A*...
  • Page 15 COOLING PERFORMANCE DATA SSZ160601B*-LOW STAGE...
  • Page 16 COOLING PERFORMANCE DATA SSZ160601B*-LOW STAGE...
  • Page 17 COOLING PERFORMANCE DATA SSZ160601B*-HIGH STAGE...
  • Page 18 COOLING PERFORMANCE DATA SSZ160601B*-HIGH STAGE...
  • Page 19: Performance Data

    PERFORMANCE DATA SSZ160241A* / CA*F3636*6A*+TXV/ MBE1600**-1 SSZ160361A* / CA*F4860*6A*+TXV/ MBE2000**-1 Conditions: 80°F IDB, 67°F IWB @ 875 CFM Conditions: 80°F IDB, 67°F IWB @ 1200 CFM Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent Total Temp. ° F. Btuh Btuh Btuh Watts...
  • Page 20 SPLIT SYSTEM HEATING PERFORMANCE SSZ160241A* EXPANDED PERFORMANCE DATA MODEL: SSZ160241A* / CA*F3636*6A* + TXV / MBE1600**-1 HEATING OPERATION Outdoor Ambient Temperature 30.2 28.6 26.9 25.1 24.0 23.3 21.6 19.9 18.7 17.3 15.9 15.0 14.4 13.0 11.5 10.0 Delta T 31.9 30.2 28.4 26.6...
  • Page 21 SPLIT SYSTEM HEATING PERFORMANCE SSZ160361A* EXPANDED PERFORMANCE DATA MODEL: SSZ160361A* / CA*F4860*6A*+TXV/ MBE2000**-1 HEATING OPERATION Outdoor Ambient Temperature 34.4 43.2 40.9 38.5 36.0 33.3 31.0 28.6 26.2 24.2 22.2 21.0 20.2 18.1 16.1 14.0 12.0 Delta T 33.4 31.6 29.7 27.8 26.5 25.7...
  • Page 22 SPLIT SYSTEM HEATING PERFORMANCE SSZ160481A* EXPANDED PERFORMANCE DATA MODEL: SSZ160481A* / CA*F4860*6A* + TXV / MBE2000**-1 HEATING OPERATION Outdoor Ambient Temperature 47.0 59.1 55.9 52.6 49.2 45.5 42.3 39.0 35.4 32.6 30.1 28.4 27.3 24.5 21.7 19.0 16.2 13.3 Delta T 35.3 33.4 31.4...
  • Page 23 SPLIT SYSTEM HEATING PERFORMANCE SSZ160601A* EXPANDED PERFORMANCE DATA MODEL: SSZ160601A* / CA*F4860*6A* + TXV / MBE2000**-1 HEATING OPERATION Outdoor Ambient Temperature 71.6 67.8 63.8 59.7 57.0 55.2 51.3 47.3 44.9 41.4 38.1 36.0 34.7 31.1 27.6 24.0 20.5 16.8 Delta T 36.9 34.9 32.8...
  • Page 24 SPLIT SYSTEM HEATING PERFORMANCE SSZ160601B* EXPANDED PERFORMANCE DATA MODEL: SSZ160601B* CAPF4961D6 MBVC2000A - LOW STAGE HEATING OPERATION Outdoor Ambient Temperature 49.9 47.3 44.5 41.6 39.7 38.5 35.8 33.0 30.8 28.4 26.2 24.7 23.8 21.3 18.9 16.5 14.1 11.5 40.2 38.1 35.8 33.5 32.0...
  • Page 25: Heating Specifications

    HEATING SPECIFICATIONS SSZ160241A* / CA*F3636*6A*+TXV/ MBE1600**-1 SSZ160361A* / CA*F4860*6A*+TXV/ MBE2000**-1 Conditions: 875 CFM @ 70°F Indoor Air Conditions: 1200 CFM @ 70°F Indoor Air Basic Unit without Capacity of Unit Basic Unit without Capacity of Unit Outdoor Outdoor Auxiliary Heat With KW of Auxiliary heat Auxiliary Heat With KW of Auxiliary heat...
  • Page 26 HEATING SPECIFICATIONS SSZ160601B* / CA*F4860*6A*+TXV/ MBE2000**-1 SSZ160601B* / CA*F4860*6A*+TXV/ MBE2000**-1 Conditions:1200 CFM @ 70°F DB, LOW STAGE Conditions:1800 CFM @ 70°F DB, HIGH STAGE Basi c Unit without Capacity of Unit Basi c Unit without Capacity of Unit Outdoor Outdoor Auxiliary Heat With KW of Auxiliary heat Auxiliary Heat...
  • Page 27 PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
  • Page 28 WIRING DIAGRAMS SSZ160[24]1AA-AF; SSZ160[36-48]1AA-AD HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 29: Wiring Diagrams

    SSZ160[60]1AA WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 30 WIRING DIAGRAMS SSZ160[60]1AB/AC/AD/AE HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 31 WIRING DIAGRAMS SSZ160[24]1AG, SSZ160[36-48]1AE HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. LVDR 0- RV C-RV HVDR Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 32 WIRING DIAGRAMS SSZ160[60]1BA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 33 WIRING DIAGRAMS SSZ160[60]1BA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS WARNING UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. LVDR 0-RV C-RV HVDR Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.