Download Print this page

Goodman SS-GPH13MC Specifications

3, 4, & 5-ton three-phase self-contained packaged heat pumps

Advertisement

13 SEER
C
C
: 34,000 - 57,500 BtU/
ooling
apaCity
h
C
: 33,800 - 57,000 BtU/
Eating
apaCity
Standard Features
• Energy-efficient compressor with internal
relief valve
• Fully charged with R-410A chlorine-
free refrigerant
• EEM blower motor; PSC blower motor
on 3-ton units
• Convertible airflow - horizontal
or downflow
• Copper tube/aluminum fin coil
• Totally enclosed, permanently lubricated
condenser fan motor
• Electric heat kit available as a field-installed accessory
Cabinet Features
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish
• Fully insulated blower compartment
with convenient access panels
• Louvered condenser coil protection
• One footprint; two heights
* Complete warranty details available from your local dealer or at
www.goodmanmfg.com.
SS-GPH13MC
gph13M C
h
h
Contents
Nomenclature .................................................................... 2
Product Specifications ....................................................... 3
Expanded Cooling Data ..................................................... 4
Expanded Heating Data . .................................................. 10
Heat Kit Electrical Data . ................................................... 11
Airflow Data .....................................................................12
Dimensions ......................................................................13
Wiring Diagrams ............................................................. 14
Accessories .......................................................................16
www.goodmanmfg.com
oMMERCial
3, 4, & 5-t
t
-p
on
hREE
haSE
S
-C
Elf
ontainEd
p
h
p
aCkagEd
Eat
UMpS
2/12
Supersedes 8/11

Advertisement

loading

Summary of Contents for Goodman SS-GPH13MC

  • Page 1: Table Of Contents

    • Heavy-gauge galvanized-steel cabinet • Attractive Architectural Gray powder-paint finish • Fully insulated blower compartment with convenient access panels • Louvered condenser coil protection • One footprint; two heights * Complete warranty details available from your local dealer or at www.goodmanmfg.com. SS-GPH13MC gph13M C 3, 4, & 5-t aCkagEd Contents Nomenclature ... 2 Product Specifications ... 3 Expanded Cooling Data ... 4 Expanded Heating Data ..10 Heat Kit Electrical Data .
  • Page 2: Nomenclature

    5   T ons www.goodmanmfg.com Engineering   Minor   R evision Engineering   Major   R evision Voltage   D esignator 1 208-­‐230/1/60     3 208-­‐230/3/60     4 460/3/60 Refrigerant 2 R-­‐22 4 R-­‐410A ConfiguraNon H Horizontal M Mul0-­‐posi0on SS-GPH13MC...
  • Page 3 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-GPH13MC GPH13 GPH13...
  • Page 4: Expanded Cooling Data

    RodUCt pECifiCationS — gph1336M43 ** xpandEd ooling www.goodmanmfg.com SS-GPH13MC...
  • Page 5 RodUCt pECifiCationS — gph1336M43 ** ( xpandEd ooling Cont SS-GPH13MC www.goodmanmfg.com...
  • Page 6 RodUCt pECifiCationS — gph1348M43** xpandEd ooling www.goodmanmfg.com SS-GPH13MC...
  • Page 7 RodUCt pECifiCationS — gph1348M43** ( xpandEd ooling Cont SS-GPH13MC www.goodmanmfg.com...
  • Page 8 RodUCt pECifiCationS — gph1360M43** xpandEd ooling www.goodmanmfg.com SS-GPH13MC...
  • Page 9 RodUCt pECifiCationS — gph1360M43** ( xpandEd ooling Cont SS-GPH13MC www.goodmanmfg.com...
  • Page 10: Expanded Heating Data

    30.2 27.1 24.0 20.9 17.9 14.6 15.5 13.9 12.3 10.8 3.83 3.73 3.64 3.55 3.46 3.37 12.8 12.4 11.8 11.4 10.8 10.2 2.31 2.12 1.93 1.72 1.51 1.27 Amps = Outdoor unit amps (comp.+fan) kW = Total system power SS-GPH13MC...
  • Page 11 Minimum Circuit Ampacity @ 208 / 240 V ² Maximum Overcurrent Protection device @ 208 / 240 V * Revision level that may or may not be designated C Circuit Breaker option SS-GPH13MC Circuit #1 Actual kW / BTU@ 240V MCA¹...
  • Page 12: Airflow Data

    1,645 1,850 1,820 1,775 1,735 2,180 2,125 2,050 1,975 www.goodmanmfg.com 1119 1041 1230 1144 1055 1,265 1,235 1,190 1,130 1,650 1,600 1,500 1,375 1,700 1,625 1,515 1,395 1,615 1,570 1,530 1,465 1,705 1,675 1,610 1,495 1,875 1,800 1,655 1,530 SS-GPH13MC...
  • Page 13: Dimensions

    Model W" D" GPH1336M43 GPH1348M43 GPH1360M43 SS-GPH13MC ilterS H" 34¾ 16" 32½" GPH13MFR102 (for medium models) 42¾ 18" 40" 42¾ 18" 40" GPH13MFR103 (for large models) www.goodmanmfg.com roduct PecificationS Model Dimensions Qty. 16” x 25” x 2” 20” x 25” x 2”...
  • Page 14 EBTDR XFMR-R XFMR-C NOTE #2   LVDR 0-RV C-RV HVDR (TRANS240V) (M1) RD (COM) BK 3 SPEED COMP Y/Y2 SEE NOTE 4 SEE NOTE PLF1 HIGH 2 SPEED OPTIONAL COMP COMPRESSOR CONTACTOR RELAY www.goodmanmfg.com LVJB Y/Y2  CONTROL SS-GPH13MC...
  • Page 15 O-RV O-RV C-RV C-RV R-DFT R-DFT R-PS1 R-PS1 1 EM 1 EM SEE NOTE 2 SEE NOTE 2 THERMOSTAT SS-GPH13MC SEE NOTE 3 SEE NOTE 5 SEE NOTE 5 BL/PK BL/PK BL/PK BL/PK COMP COMP COMPONENT LEGEND COMPONENT LEGEND CONTACTOR...
  • Page 16 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2012 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. Description www.goodmanmfg.com SS-GPH13MC...

This manual is also suitable for:

Gph1336m43 seriesGph1348m43 seriesGph1360m43 series