Advertisement

Dispense wheel and waterbath bath cover removal
1. Remove grille and drain pan assembly.
2. Remove center thumbnut and threaded rod on dispense wheel assembly
3. Remove two (2) screws holding bath cover in place and lift cover out front.
Disassembly instructions for service requirements only – NOT required for
any cleaning procedure.

Wheel motor removal

1. Remove dispense wheel and ice-waterbath cover plates (see instructions above).
2. Remove spacer and shaft seal.
3. Lift motor bracket up and unplug electric quick disconnects.
Ice-waterbath pump motor removal
1. Remove wheel motor.
2. Drain ice-waterbath by lowering drain tube on utility connection side of dispenser.
3. Slice insulation enough to expose hose clamps on intake, output and recirculating system fittings.
4. Loosen clamps and pull tubing off fittings.
5. Loosen screws on pump motor bracket.
6. Slide pump bracket off mounting screws.
7. Disconnect electric wires from pump and remove pump.
and lift wheel out front (see photo above).