Installation Precautions - HP 2510-24 Installation And Getting Started Manual

Procurve series
Hide thumbs Also See for 2510-24:
Table of Contents

Advertisement

Installing the Switch
Installation Procedures

Installation Precautions:

Follow these precautions when installing the Series 2510 Switch.
W A R N I N G
C a u t i o n s
2-4
The rack or cabinet should be adequately secured to prevent it
from becoming unstable and/or falling over.
Devices installed in a rack or cabinet should be mounted as low as
possible, with the heaviest devices at the bottom and progressively
lighter devices installed above.
For safe operation, do not install the switch with the with the vents
facing either downward.
Left side vents cannot be placed downward. (That is, the left side
of the unit while facing the front.)
Ensure the power source circuits are properly grounded, then use the
power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied
with the switch, be sure the cord is adequately sized for the switch's
current requirements. In addition, be sure to use a power cord displaying
the mark of the safety agency that defines the regulations for power cords
in your country. The mark is your assurance that the power cord can be
used safely with the switch.
When installing the switch, the AC outlet should be near the switch and
should be easily accessible in case the switch must be powered off.
Ensure the switch does not overload the power circuits, wiring, and over-
current protection. To determine the possibility of overloading the supply
circuits, add together the ampere ratings of all devices installed on the
same circuit as the switch and compare the total with the rating limit for
the circuit. The maximum ampere ratings are usually printed on the
devices near the AC power connectors.
Do not install the switch in an environment where the operating ambient
temperature might exceed 45°C (113°F).
Ensure the air flow around the sides and back of the switch is not
restricted.