Cartridge Specifications; Filter Cartridge Replacement - GE SmartWater GXWH30C Installation Instructions Manual

Heavy duty water filtration system
Hide thumbs Also See for SmartWater GXWH30C:
Table of Contents

Advertisement

Available languages

Available languages

Performance Data
This system has been tested according to ANSI/NSF 42
for the reduction of the substances listed below. The
concentration of the indicated substances in water
entering the system was reduced to a concentration
less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42.

Filter Cartridge Replacement

You should change your filter when the water flow is noticeably reduced or at least every three months.
Turn off water to filter. Water must be shut off
1
from an upstream valve.
Press the red pressure release button to release
2
pressure.
Unscrew the filter canister and discard used
3
filter. Wash the filter canister with mild soap
and water. Do not use harsh cleaners or hot
water.
Inspect the filter canister O-ring. Make sure
4
it is lightly lubricated and completely seated
in the groove. It is recommended that you
replace the O-ring if it is damaged.
Place a new filter cartridge into the canister,
5
making sure it is centered and completely
seated on the bottom seal.
Reinstall the filter canister to the unit. Hand
6
tightening is all that is required to seal the
unit. DO NOT OVERTIGHTEN.
Installation Overview
NOTE: Be sure to allow a minimum space
"–2" under the filter for removing
of 1
1
2
the sump to change the cartridge.

CARTRIDGE SPECIFICATIONS

FXHTC Cartridge
Substance
Standard 42
Chlorine
Test Conditions
Flow Rate: 3 gpm (11.4 Lpm)
pH: 7.5±1
Inlet Pressure: 60 PSI (4.1 bar)
Temperature: 68°F ± 5°F (19.8°C ± 2.5°C)
Testing was performed under standard laboratory conditions, actual performance may vary.
Slowly turn on water to the filter by using the
7
upstream shut-off valve.
Press the red pressure release button to
8
remove trapped air.
After installation, flush the cartridge for
9
10 minutes, wait one hour, then flush again
for 10 minutes before using the water.
Filter
cartridge
Turn
clockwise
to remove
canister
STEP-BY-STEP INSTALLATION INSTRUCTIONS
Ferrule
Hex nut
Recommended
shut-off valve
2
Influent Challenge
Concentration
2.0 mg/L ±10%
Red pressure
release button
Head
O-ring seal
Filter canister
Turn
counterclockwise
to tighten
Hex nut
Ferrule
Adapter
Adapter
"–2"
1
1
2
Reduction
Requirements
≥50%
Operating Requirements
Pressure: 30–100 PSI (2.1–6.9 bar)
Turbidity: 5 NTU Max.
Temperature: 40°F–100°F (4.4°C–37.7°C)
Capacity: 5,000 gallons (18,927L) or 3 months
Turn sump wrench tool
clockwise to remove
Recommended
shut-off valve
Typical installation
Average
Reduction
95.5%
Sump

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents