Bryant 352MAV Installation, Start-Up, And Operating Instructions Manual page 28

Series b, 2-stage, direct vent condensing gas furnace
Table of Contents

Advertisement

ALTITUDE (FT)
UNIT SIZE
036060
036080
048080
4001 to 5000‡
048100
060100
060120
ALTITUDE (FT)
UNIT SIZE
036060
036080
048080
5001 to 6000‡
048100
060100
060120
ALTITUDE (FT)
UNIT SIZE
036060
036080
048080
6001 to 7000‡
048100
060100
060120
ALTITUDE (FT)
UNIT SIZE
036060
036080
048080
7001 to 8000‡
048100
060100
060120
See notes at end of table.
WARNING: Inducer housing outlet cap must be in-
stalled and fully seated against inducer housing. Clamp
must be tightened to prevent any condensate leakage.
Failure to follow this warning could result in electrical
shock, fire, personal injury, or death.
c. Install pipe support (factory-supplied in loose parts bag)
into selected furnace casing vent pipe hole. Pipe support
should be positioned at bottom of casing hole.
d. Be certain that mating surfaces of inducer housing
connection, elastomeric coupling, and 2-in. diameter
vent pipe are clean and dry. Assemble the elastomeric
(rubber) vent coupling (with 2 loose clamps) onto
inducer housing connection. Insert the 2-in. diameter
vent pipe through the elastomeric (rubber) coupling and
fully into inducer housing connection until it bottoms on
the internal stop. Tighten both clamps to secure the pipe
to inducer housing. Tighten the clamp screws to 15
in.-lb. of torque.
TABLE 7-MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED)
TERMINATION
TYPE
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 3-in
Concentric
2 Pipe or 3-in.
Concentric
TERMINATION
TYPE
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 3-in
Concentric
2 Pipe or 3-in.
Concentric
TERMINATION
TYPE
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 3-in
Concentric
2 Pipe or 3-in.
Concentric
TERMINATION
TYPE
2 Pipe or 2-in
Concentric
2 Pipe or 2-in
Concentric
2 Pipe or 3-in
Concentric
2 Pipe or 3-in.
Concentric
PIPE DIA
(IN.)*
1
2
1-1/2
15
10
2
64
59
2
44
39
2-1/2
70
70
2-1/2
31
22
3
70
70
3† no disk
53
46
4† no disk
70
70
PIPE DIA
(IN.)*
1
2
1-1/2
14
9
2
60
55
2
41
36
2-1/2
70
70
2-1/2
29
21
3
70
67
3† no disk
42
35
4† no disk
70
70
PIPE DIA
(IN.)*
1
2
1-1/2
13
8
2
57
52
2
38
33
2-1/2
70
70
2-1/2
27
19
3
68
63
3† no disk
31
24
4† no disk
70
70
PIPE DIA
(IN.)*
1
2
1-1/2
12
7
2
53
48
2
36
31
2-1/2
66
65
2-1/2
25
17
3
63
58
3† no disk
20
13
4† no disk
61
56
3/8" ID TUBE
3/16"
DRILL
MIN
TRAP
TO OPEN
DRAIN
Fig. 36—Intake Housing Plug Fitting Drain
e. Install casing hole filler plug (factory-supplied in loose
parts bag) in unused combustion-air pipe casing hole.
—28—
NUMBER OF 90° ELBOWS
3
4
5
5
NA
NA
58
53
52
26
21
20
70
70
70
13
12
NA
67
62
57
40
33
26
70
70
70
NUMBER OF 90° ELBOWS
3
4
5
NA
NA
NA
54
49
48
23
18
17
70
70
70
12
11
NA
62
57
52
29
22
15
70
70
70
NUMBER OF 90° ELBOWS
3
4
5
NA
NA
NA
50
45
44
21
16
15
68
67
66
10
9
NA
58
53
48
18
11
NA
70
70
67
NUMBER OF 90° ELBOWS
3
4
5
NA
NA
NA
46
41
40
19
14
12
63
62
60
8
7
NA
53
48
43
7
NA
NA
51
46
41
COMBUSTION – AIR
INTAKE HOUSING
4"
6
NA
52
11
70
NA
52
20
70
6
NA
47
8
70
NA
47
9
70
6
NA
43
6
64
NA
43
NA
62
6
NA
38
NA
59
NA
38
NA
36
BURNER
BOX
COMBUSTION –
AIR PIPE
A93035

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents