Connect The Vent System - KitchenAid 9763393A Installation Instructions And Use And Care Manual

30" (76.2 cm) and 36" (91.4 cm) slide-out vent range hood
Table of Contents

Advertisement

Available languages

Available languages

3. Connect the black wire of the power supply cable to the
black wire in the hood with a twist-on connector.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death or electrical shock.
4. Connect the power supply ground wire to the green ground
screw inside the vent hood terminal box.
B
C
A. White wires
B. Green ground screw
C. Ground wire
5. Replace the terminal box cover.

Connect the Vent System

Vented installations:
Replace the metal filter. Connect the vent system to the hood
vent opening. Seal the connection with clamps.
A
A. Filter
A
E
D
D. Black wires
E. Twist-on connectors
Recirculation installations:
Connect the vent system to the hood vent opening. Seal the
connection with clamps.
Install Recirculation Kit (Part Number 883140)
1. Pull out on the range hood to expose the filters.
2. Remove the 2 metal filters.
3. Locate tabs "A" and slots "B" in the opening. This is where
the filter will fit into place.
B
A. Tab
B. Slot
4. Place charcoal filter into opening, resting the back of the filter
on tabs "A," then clip filter tabs "C" into slots "B."
B
A. Tab
B. Slot
C. Filter tabs
5. Replace metal filters.
6. Reconnect power.
7. Check the operation of the vent hood fan and light.
8. Push the range hood back in.
To order replacement kits, see the "Assistance or Service"
section.
A
C
A
A