Canceling Interfering Signal (Interference); Repositioning/Hiding The Depth Scale Display (Scale Position) - JRC JFC-130 Instruction Manual

Color echo sounder
Hide thumbs Also See for JFC-130:
Table of Contents

Advertisement

< Canceling Interfering Signal (INTERFERENCE)
An interference canceler is available to cancel interfering signals coming
from fishfinders mounted on other boats. The interference canceler has four
settings: OFF, 1, 2, and AUTO. Choose "1" to cancel weak interfering
signals, "2" to cancel strong interfering signals. "AUTO" will activate the
canceler to suit the strength of the interfering signals. "OFF" disables the
canceler.
Normally, interference canceler is used at the OFF position. Switch it to 1 if
interferences are observed. The interference value can be monitored from
the fishfinding display (see page 10).
To choose the interference canceler, follow these steps:
1.
Press the
and
menu.
2.
Using the
MARK
key.
3.
Press the
key to move to "2.INTERFERENCE."
4.
Press the
or
5.
Press the
key to return to the main menu.
MARK
6.
Press the
GRAPH
key to return to the fishfinding display.
< Repositioning/Hiding the Depth Scale Display (SCALE POSITION)
The depth scale display appears onscreen. If its position interferes with the
sight of the display image, you can reposition or hide its display.
To reposition or hide the depth scale display, follow these steps:
1.
Press the
and
menu.
2.
Using the
MARK
key.
3.
Press the
or
4.
Press the
or
of five positions.
5.
Press the
MARK
key to return to the main menu.
6.
Press the
GRAPH
key to return to the fishfinding display.
keys at the same time to call up the main
or
key, move to "9.DISPALY" and press the
key to move to "OFF," "1," "2," or "AUTO."
keys at the same time to call up the main
or
key, move to "9.DISPALY" and press the
key to move to "3.SCALE POSITION."
key to move to "DISP OFF"(hide) or any one
1.PRESET STD RANGE ≫
10
20
RANGE 60
80 100 150 200
11 12 13 14 15
250 300 400 500 800
STEP
10
▲ 2.BTM EXP.RANGE
2
3
▼ 3.B.DISCRIM RANGE ≫
10
20
30
4.VRM EXP.RANGE
5
10
15
5.STD RANGE MODE
PRESET STEP AUTO
6.BACK COLOR
NORMAL 1
2
7.COLOR MODE
NORMAL 1
2
8.USER COLOR
9.DISPLAY
10.SET GRAPH
≫ DEPTH/ DEPTH/
TEMP
BH
11.UNIT
GRAPH : RETURN TO F/F
MARK : GOTO SUB MENU
Main Menu
9.DISPLAY
DISPLAY
1.TEMP.POSITON
DISP OFF
2.INTERFERENCE
OFF 1 2 AUTO
3.SCALE POSITION
DISP OFF
4.FINE SCALE
AUTO 1 2 5 10 20 50 100
▲ 5.VRM
DISP OFF DISP ON
▼ 6.COLOR SAMP.
DISP OFF DISP ON
7.DEPTH POSITION
DISP OFF
8.SPLIT DISP.MODE
9.BTM/VRM EXP.AREA
1/3 1/2 ALL
10.A-SCP MODE
LOG LINEAR
MARK : RETURN TO MENU
DISPLAY
2. INTERFERENCE
DISPLAY
1.TEMP.POSITON
DISP OFF
2.INTERFERENCE
OFF 1 2 AUTO
3.SCALE POSITION
DISP OFF
4.FINE SCALE
AUTO 1 2 5 10 20 50 100
▲ 5.VRM
DISP OFF DISP ON
▼ 6.COLOR SAMP.
DISP OFF DISP ON
7.DEPTH POSITION
DISP OFF
8.SPLIT DISP.MODE
9.BTM/VRM EXP.AREA
1/3 1/2 ALL
10.A-SCP MODE
LOG LINEAR
MARK : RETURN TO MENU
DISPLAY
3. SCALE POSITION
Operation
30
40
50
9 10
4
5
10
40
50
20
50
3
3
25