Simultaneous (Twin) -Type
1-1. Unit Specifi cations
Ceiling Type S-60PT1E5×2 / U-125PE1E8
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
SEER
(W/W)
Erp
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE ( MAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
I/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
COOL
m
3
/min (ft
O/D AIR
FLOW
3
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
P
PIPE LENGTH RANGE
I
I/D&O/D HEIGHT DIRRERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2 If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-60PT1E5×2
-
ø, Hz
1ø 50Hz
V
220
230
kW
12.5
12.5
42700
42700
A
0.53×2
0.52×2
W
52×2
52×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
39/36/33
58/53/50
dB-A
kW
14.0
14.0
47800
47800
A
0.53×2
0.52×2
W
52×2
52×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
40/36/33
58/53/50
dB-A
-
-
0.53×2/52×2 0.52×2/52×2 0.52×2/52×2 10.0/6.200k
-
-
-
40×2
L/h(Pt/h)
7.9 (3.95×2)
Pa (mmAq)
-
3
/min)
19×2
3
/min)
19×2
3
/min)
3
/min)
210 (8-9/32)
1180 (46-15/32)
680 (26-25/32)
280
1255
780
25 (55)
28 (62)
11 (12)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-125PE1E8
-
ISO5151 / EN14825
3ø 50Hz
240
380
400
12.5
42700
0.52×2
6.10
5.80
52×2
3.775k
3.774k
3.880k
3.880k
-
1940
-
3.22
3.22 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
94
94
53/-
70/-
14.0
47800
0.52×2
5.80
5.50
52×2
3.576k
3.575k
3.680k
3.680k
-
3.80
3.80 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
94
-
-
53/-
70/-
-
10.0/6.500k
-
6.10/3.0k
5.80/3.0k
-
90×2
(16.6)
-
(671)×2
(671)×2
130
110
R410A
3.40k
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
(49.2/98.4)
50
(537.6)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-49
415
Min
Max
3.3
14.0
11300
47800
5.60
-
-
3.772k
-
-
3.880k
840
4.600k
-
-
-
3.22
3.93
3.04
-
-
-
-
94
-
-
4.1
16.0
14000
54600
5.30
-
-
3.574k
-
-
3.680k
900
5.200k
3.80
4.56
3.08
-
-
-
-
-
94
-
-
⁄
⁄
⁄
⁄
10.0/6.750k
⁄
5.60/3.0k
⁄
⁄
(4591)
(3885)
(119.9)
/
/
/
/
/
/
/
/
/
~
~
1