G. Service Information
The SERVICE INFORMATION screen displays contact in-
formation for Hearth & Home Technologies Customer Ser-
vice Line. The local dealer may have changed this upon or
before the installation to indicate a dealer hot line.
www.quadrafire.com
to locate your nearest
dealer
DONE
Figure 21.1
H. Error Codes
If a system error occurs that forces the system to stop op-
erating an error screen appears. Depending upon the error
type, up to three retry attempts are allowed after which a
service professional is required.
Press the ERROR LIST button to display the latest error.
See page 28 for a list of error codes.
I. Battery Back-up System (Optional)
CAUTION!
• Hook up to battery terminals BEFORE you plug battery
into appliance.
• Damage to internal electronic components may occur.
The appliance has been designed to operate on an optional
battery back-up system.
If you have frequent power outages in your region, hook
the appliance up to a 12 volt battery and it will automatically
switch to battery power in the event of a power failure. The
12 volt power cord sold as a separate accessory does not
charge the battery.
MANUAL LIGHT PROCEDURE
Press "CONTINUE"
button to start manual
lighting sequence
Current Tem: 72 F
MANUAL LIGHT PROCEDURE
Please wait while
feed charge is loading
MANUAL LIGHT PROCEDURE
Manually light fuel...
Figure 21.2
January 29, 2014
ERROR LIST
O
CONTINUE
into firepot
Open door...
Close door
Refer to page ___ for instructions on how to attach the cable
to appliance. The following are screens you will see when
using a back-up battery.
Operating on Battery Back-Up
A battery icon appears on your wall control to let you know
you are now operating on battery power. Figure 21.3.
• Fire must be manually lit as the appliance will no longer
automatically light. See section G on page 21.
Use only approved fire starting gel to start fire.
• High burn rate is no longer available on battery back-up.
Each level drops down one level,
comes medium-high burn and so on.
• If the battery charge falls below 10 volt it can no longer
sustain the appliance operation and the appliance will
shut down. You must disconnect and reconnect the bat-
tery to start it up again.
Recommended Battery
• 12 volt deep cycle battery, (i.e., marine or RV type).
A 12 volt battery cable is available through your local
dealer.
WARNING! Risk of Injury!
• Blowers may continue to run and would be exposed to
human contact.
13 Volts
Figure 21.3
Wall Control Display
The wall control will display the battery icon when operating
in the battery back-up mode. Figure 21.4.
"Maint Burn" will display when
the thermostat has reached the
set room temperature and will
run on low until it reaches its
auto-clean cycle time.
MAINT BURN
73
MENU
Figure 21.4
7036-187
MT. VERNON AE INSERT
i.e the high burn be-
12 Volts
11 Volts
12:30 PM
Set at: 73
HEAT OUTPUT
Battery icon.
Battery
Below
10 Volts
21