Congratulations; Sample Of Serial Number / Safety Label - Quadra-Fire MTVERNINSAE-MBK Owner's Manual Operation & Care

Mt vernon pellet insert advanced energy (ae)
Hide thumbs Also See for MTVERNINSAE-MBK:
Table of Contents

Advertisement

MT. VERNON AE INSERT
A. Congratulations
Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.
This commitment begins with our research of the market,
including 'Voice of the Customer' contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world's most
advanced technology to achieve the optimum opera-
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
B. Sample of Serial Number / Safety Label
LOCATION: On Beaded Chain on e behind Right Side Panel
Test Lab &
Report No.
2
and Welcome to the Quadra-Fire Family
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
:
BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit only with fuel hopper lid closed. Failure to do so
may result in emission of products of combustion from the hopper under certain conditions. Maintain hopper
seal in good condition. Do not overfill hopper.
ATTENTION:
CHAUD LORS DE L' O PÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L' E SPACE
DÉSIGNÉ DE L' I NSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L' É TIQUETTE ET LES
INSTRUCTIONS. Opérez cet apparei l avec l e couvercl e de l a trémi e fermé. Le défaut de ne pas sui v re l e s i n structi o ns peut résul t er,
sous certai n es condi t i o ns, en une combusti o n des émi s si o ns des produi t s venant de l a trémi e . Ne pas rempl i r l a trémi e trop pl e i n e.
SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ
Tested and
O-T L
Portland
Listed by
Oregon USA
Report / Rapport
C
US
#061-S-69-6
Mt. Vernon Pellet Insert AE
OMNI-Test Laboratories, Inc.
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home
Installation. This appliance has been tested and listed for use in Manufactured
Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating Pellet
Burning Type, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD. SEE OWNER'S
MANUAL FOR OTHER FUEL OPTIONS.
OMNI-Test Laboratories, Inc. has determined that this appliance complies with
Canadian Standards Association (CSA) B415.1 and Title 40 of the U.S. Code of
Federal Regulations, Part 60, SubPart AAA.OMNI-Test Laboratories Accrediations:
The Standards Council of Canada, the American National Standards Institute, and the
U.S. Environmental Protection Agency.
I
nput Rating: 60,000 BTU/HR.
Electrical Rating: 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing.
Replace glass only with 5mm ceramic available from your dealer.
T
o start, set thermostat above room temperature, the stove will light automatically. To
shutdown, set thermostat to below room temperature. For further instruction refer to
owner's manual.
Keep viewing and ash removal doors tightly closed during operation.
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation and operating instructions.
Contact local building or fire officials about restrictions and inspection in our area.
WARNING: FOR MOBILE HOMES: Do not install appliance in a sleeping room. An
outside combustion air inlet must be provided. The structural integrity of the mobile home
floor, ceiling and walls must be maintained.
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling. Inspect and clean vent system frequently
in accordance with manufacturer's instructions.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
Use a 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
AS A BUILT-IN UNIT
A
A Top of Hopper
Top/Rear Vent
3 in. (76mm)
B Side of Outside Skin
Top/Rear Vent
2 in. (51mm)
C
C Back of Hopper
Top Vent
7.5 in. (191mm)
Rear Vent
2.75 in. (70mm)
D Vent Pipe to Combustible Top/Rear Vent
3 in. (76mm)
0 in. Clearance To Exposed Section and Face Trim / Espace libre
E Cast Side to Side Wall Top/Rear Vent
6 in (152mm)
de 0 mm de la section exposée et de la garniture du devant.
Masonry or Zero Clearance
Garniture
de façade
MANTEL
MANTEAU
Face Trim
See manual for mantel clearances.
A Insert side to combustible
B Insert top to face trim
B
C Insert side to face trim
D Hearth extension from door opening
C
A
E Hearth extension from side of door opening
de l'ouverture de la porte
*When constructing floor protection for your pellet appliance, any parts or materials used, must be non-combustible.
E
D
* Lors de la construction de protection de sol pour votre appareil à granules, toute pièces ou matériaux utilisés, doivent être incombustibles.
DO NOT REMOVE THIS LABEL
:
Manufactured by:
Fabriqué par
2012 2013 2014
JAN
Made in U.S.A.
1445 North Highway, Colville, WA 99114
www.quadrafire.com
U.S ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "air-to-fuel ration"].
7036-187
tion of our stoves, inserts and fireplaces. And yet we are
old-fashioned when it comes to craftsmanship. Each unit
is meticulously fabricated and gold and nickel surfaces are
hand-finished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection.
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Quadra-Fire.
SERIAL NO. / NUMÉRO DU SÉRIE
007002
R
Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans
l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage
dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
Testé à: ASTM #1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating. Pellet Burning Type,
UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS. VOIR LE MANUAL DU PROPRIÉTAIRE
POUR D'AUTRES OPTIONS DE CARBURANT.
OMNI-Test Laboratories, Inc. a déterminé que cet appareil se conforme avec la norme de l'Association
Canadienne de normalisation (CSA) B415.1 ainsi que le Titre 40 du Code Fédéral de Régulations des
États-Unis, partie 60, sous-partie AAA. Accréditations OMNI-Test Laboratories : Le Conseil Canadien
des Normes (CCN/SCC), l'Institue des Standards Nationaux Américain (ANSI) et l'Agence de Protection
Environnemental (EPA).
Puissance de Rendement: 60,000 BTU/HR
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps,
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera
automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la
pièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture
et la porte des cendres fermées hermétiquement durant l'opération.
PRÉVENTION DES FEUX DE MAISON
Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le bureau
de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation dans
votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une chambre à coucher. Un tuyau extérieur de
combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure
intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.
Référez vous aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une
cheminée à travers un mur ou un plafond combustibles, et les compensations maximums.
Inspectez et nettoyez la cheminée fréquemment.
NE PAS CONNECTER CETTE UNITÉ À UN CONDUIT DE CHEMINEE DESSERVANT UN AUTRE APPAREIL.
Utilitsez le système de ventilation de 3 or 4 inch (76-102mm) de diametre de type "L" ou "PL".
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
COMME APPAREIL INSÉRÉ
C
D
A Des Conduits Du Haut/Arrières: 3 in. (76mm)
B
B Des Conduits Du Haut/Arrières: 2 in. (51mm)
B
C Des Conduits Du Haut:
Arrières
E
D Des Conduits Arrières/Du Haut 3 in. (76mm)
E Côté de Fonte au Mur Latéral: 6 in. (152mm)
Dégagement de la maçonnerie ou Dégagement zéro*
/ Insérez le côté au mur combustible latéral
/ Insérez le dessus de la garniture de façade
/ Insérez le côté de la garniture de façade
/
Prolongement d'âtre depuis l'ouverture de la porte devant
/ Prolongement d'âtre depuis le côté
NE PAS ENLEVER L'ÉTIQUETTE
FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC
Fabriqué aux États-Unis-d'Amérique par des
of US and
pièces d'origine américaine et pièces
imported parts.
importées.
!
Model
Name
Serial No.
7.5 in. (191mm)
2.75 in. (70mm)
6 in.
152mm
0 in.
0mm
0 in.
0mm
6 in.
152mm
6 in.
152mm
Mfg. Date
7036-137H
January 29, 2014

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mtverninsae-pmhMtverninsae-csb

Table of Contents