SPECIFICATIONS
REPLACEMENT PARTS
SERVICE HINTS
TECHNICAL SERVICE
SPECIFICATIONS
Thermostat Models:
VMH1OTPB, EFS1OTP
Thermostat Models:
VMH1OTNB, EFS1OTN
Remote-Ready Models:
VMH26PRA, EFS26PR,
FMH26PR
Remote-Ready Models:
VMH26NRA, EFS26NR,
FMH26NR
Btu/Hr
10,000
10,000
14.000/26,000
14,000/26,000
Type Gas
Propane/LP Gas Only
Natural Gas Only
Propane/LP Gas Only
Natural Gas Only
Ignition
Piezo
Piezo
Piezo
l'iezo
Manifold Pressure
8.5" W.F.
8" W.C.
3.5" W.C.
Inlet Gas Pressure
(in. of water)
Maximum
14"
10.5"
4''
10.5"
Minimum*
11"
11"
Dimensions, inches (lixWxD)
Fireplace
25 it /s x 26 "
fit
x 9 3 /8
(including hood
and screws)
25 7 /s x 26 13
/16 X
9 'R
25
x 26
x 9 3 /s
25 'Is x 26 "
Is
X
9 3/8
Carton
32
x 27 ' 3/16 x 11 Vg
32
78. X
27 13
/la
x II cis
32 '/s x 27 13/16 x 11 5 /2
32 '4 x 27 L7
11 'Is
Weight, pounds
Fireplace
44
72
lbs.
44 Is lbs.
44
71
lbs.
44
7
2
lbs.
Shipping
48 lbs.
48 lbs.
48 lbs.
48 lbs.
* For purpose of input adjustment
REPLACEMENT PARTS
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply
original replacement part(s), call DESA Heating Products Techni-
cal Service Department at 1-866-672-6040.
When calling DF.SA Heating Products, have ready
•
your name
•
your address
•
model and serial numbers of your fireplace
•
how fireplace was malfunctioning
•
type of gas used (propane/I.P or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply original
replacement part(s). call DESA Heating Products at 1-866-672-6040
for referral information.
SERVICE HINTS
•
pilot will not stay lit
•
burners will have delayed ignition
•
fireplace will not produce specified heat
•
for propane/LP units. propane/LP gas supply may he low
You may feel your gas pressure is too low. If so, contact your local
natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA Heating Products' Technical
Service Department at 1-866-672-6040. When calling, please have
your 'node] and serial numbers of your heater ready.
You can also visit DESA Heating Products' technical services well
site at
www.desatech.com .
Note:
Use only original replacement parts. This will protect your
When Gas Pressure Is Too Low
warranty coverage for parts replaced under warranty.
When calling DE:SA Heating
Products,
have ready
•
model number of your fireplace
•
the replacement part number
s1SS3 5i'disiii
e eit
ly_Le
www.desatech.com
MESA
'07032.01J