Control Via Rs-485 Interface - Samsung SCB-5003 User Manual

Supreme resolution wdr camera
Hide thumbs Also See for SCB-5003:
Table of Contents

Advertisement

When the resistance value of copper wire is at [20°C(68°F)]
Copper wire size (AWG)
Resistance value(Ω/m)
Voltage Drop (V/m)
As shown in the table above, voltage decreases as the wire gets longer.
Therefore use of an excessively long adaptor output line for connection to the camera
may affect the performance of the camera.
Standard voltage for camera operation : DC 12V±10%, AC 24V±10%
There may be some deviation in voltage drop depending on the type of wire and the
manufacturer.
M
Be sure to connect power only after all the installation is complete.

ConTrol Via rs-485 inTErfaCE

The camera can be controlled by using external controllers like a Remote controller. (RS-485
Communication)
(1) To control by PC
Connect the RS-485 control port of the camera and the serial cable through an RS-485
converter.
Example) PC Serial Port (COM1)  Serial Cable RS-485 Converter  Camera RS-485Control Port.
(2) To control using a DVR or System Controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of the 485 control board
that is connected to the DVR or System Controller.
485 Control Board Connection Port
(+) CONNECTION TERMINAL (TRX+)
(- ) CONNECTION TERMINAL (TRX-)
* RS-485 Communication establishment initial value
Item
Camera ID
Initial value
M
To control the camera by constructing an additional controller, use the SAMSUNG-T, SAMSUNG-E,
PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON and PANASONIC, GE, AD protocol.
#24 (0.22mm
)
2
0.078
0.028
BAUD RATE
1
9600
#22 (0.33mm
)
#20 (0.52mm
2
0.050
0.030
0.018
0.011
RS-485 Control Port
UART MODE
8-NONE-1
)
#18 (0.83mm
2
0.018
0.006
485+
485-
RET PKT
ENABLE
English_1
)