Reset Connector
The reset connector is located on pins 3
and 4 of JF1 and attaches to the reset
switch on the computer chassis. See the
table on the right for pin defi nitions.
Power Fail LED
The Power Fail LED connection is located
on pins 5 and 6 of JF1. Refer to the table
on the right for pin defi nitions.
Overheat/Fan Fail/UID LED
Connect an LED cable to pins 7 and 8 of
JF1 for the Overheat/Fan Fail and UID
LED connections. The red LED (pin 8)
provides warning of an overheat or fan
failure. The blue LED (pin 7) works as the
UID LED indicator for the front panel UID
button located on pins 13~14 of JF1. When
Jumper J_UID_OW is set to off (default),
the red LED takes precedence over the
blue LED. Refer to the tables on the right
for more information.
NIC2 (LAN2) LED
The LED connections for LAN2 are on pins
9 and 10 of JF1. Attach an LED cable to
display network activity. See the table on
the right for pin defi nitions.
NIC1 (LAN1) LED
The LED connections for LAN1 are on pins
11 and 12 of JF1. Attach an LED cable to
display network activity. See the table on
the right for pin defi nitions.
Reset Button
Pin Defi nitions (JF1)
Pin#
3
4
PWR Fail LED
Pin Defi nitions (JF1)
Pin#
5
6
OH/Fan Fail/Blue_UID LED Pin
Defi nitions (JF1)
Pin#
Defi nition
7
Blue_LED-Cathode(UID)/5.5V.SB
8
OH/Fan Fail/UID LED (Red)
OH/Fan Fail LED Status
State
Off
On
Flashing
Pin Defi nitions (JF1)
Pin#
9
10
Pin Defi nitions (JF1)
Pin#
11
12
5-16
Defi nition
Reset
Ground
Defi nition
3.3V
PWR Fail LED
(Red LED)
Defi nition
Normal
Overheat
Fan Fail
NIC2 LED
Defi nition
Activity LED
Link LED
NIC1 LED
Defi nition
Activity LED
Link LED