Specification - Viessmann VITODENS 222-F Installation And Service Instructions Manual

Compact gas condensing boiler 4.8 to 35 kw natural gas and lpg version gc no 47-819-15 (19kw); 47-819-16 (26kw); 47-819-17 (35kw)
Table of Contents

Advertisement

Specification

Rated voltage
Rated frequency
Rated current
Protection class
Protection
Permissible ambient temperature
■ during operation
■ during storage and
transport
Gas boilers
Rated output range
at T
/T
50/30 °C
F
R
for DHW heating
Rated thermal load
range
for central heating
Power consumption
(max.)
Connection values
in relation to the max.
load
Natural gas H
LPG
Product ID
Note
The supply values are only for documentation purposes (e.g. in the gas contract
application) or to estimate the supplementary volumetric settings. Because of factory
settings, the gas pressure must not be altered from these settings. Reference: 15 °C,
1013 mbar.
230 V
Electronic tempera-
50 Hz
ture limiter setting
6 A
Temperature limiter
E
setting
IP X 4 D to
Line fuse (mains)
EN 60529
0 to +40 °C
-20 to +65 °C
kW
4.8 to 19
kW
4.3 to 17.2
kW
4.5 to 17.9
W
150
1.89
m
3
/h
kg/h
1.40
Specification
82 °C
100 °C (fixed)
max. 16 A–
6.5 to 26
5.9 to 29.3
6.2 to 30.5
150
3.23
2.39
_-0085 BU 0051
8.8 to 35
7.9 to 31.7
8.3 to 34.9
160
3.86
2.85