Warning/Error Messages

If battery power is low or a problem occurs at power on or
during operation, a warning is given by an indicator
Viewfinder screen
Basic status
Message
display (page 50)
BATT 12 V flashing
BATT 12 V quick
flashing
BATT 24 V flashing
BATT 24 V quick
flashing
TEMPERATURE CARE
TEMP WARNING/FAN
MAX
SHUTDOWN CAMERA/
FAN MAX
OHB/SIDE FAN NG!
PS FAN NG!
CAM?
OHB NG!
CAM?
AD BOARD NG!
CAM?
DPR BOARD NG!
CAM?
VDA BOARD NG!
CAM?
TR BOARD NG!
CAM?
AT BOARD NG!
IF BOX NG!
OPT CA NG!
UNKNOWN RECORDER
VTR ALARM
VTR WARNING
LASER SHUTDOWN!
REC DPR BOARD NG!
REC VTR NO SDI
INPUT!
REC VTR MISSING!
REC PB CRC ERROR!
REC PB GREY!
1) Recording error messages:
When using an SRW-1 mounted on the F35 or connected to the F35 via an
optic cable, a message is displayed if abnormality is detected in recording
on the SRW-1. The RUN indicator and tally lamp of the camera and the red
Subdisplay
BATT 12 V flashing Flashing
BATT 12 V quick
flashing
BATT 24 V flashing Flashing
BATT 24 V quick
flashing
1)
1)
1)
1)
1)
flashing or various alarm indications.
RUN
Meaning
indicator
Voltage of the 12 V power becomes low,
reaching the specified NEAR END value.
Quick
Voltage of the 12 V power becomes too
flashing
low, reaching the specified END value.
Voltage of the 24 V power becomes low,
reaching the specified NEAR END value.
Quick
Voltage of the 24 V power becomes too
flashing
low, reaching the specified END value.
Temperature inside the camera raises.
Temperature inside the camera raises to
the limit. FAN MODE is forcibly set to MAX.
The camera must be turned off for safety.
FAN MODE is forcibly set to MAX.
The fan near the CCD or the fan near the
side panel stops.
The fan near the power unit stops.
Abnormality of the CCD unit
Abnormality of the AD board
Abnormality of the DPR board
Abnormality of the VDA board
Abnormality of the TR board
Abnormality of the AT board
Abnormality of the interface box
Abnormality of the CA-F101
An unknown recorder is connected.
Alarm occurs at the SRW-1.
Warning occurs at the SRW-1.
The laser-module protection circuit has
been activated with the CA-F101 mounted.
For details, refer to the Operation Manual
of the CA-F101.
Abnormality of the DPR or TR board
NO SDI INPUT error from the VTR
received
Communication with VTR shut off
CRC error detected in the PB signal from a
VTR
Gray signal over the entire screen detected
in the PB signal from a VTR
tally of the viewfinder flash quickly. Displayed message may vary
depending on the contents of error. While the alarm indication is activated
only during recording, it cannot be cleared until you turn off power.
133