Electrical Adjustment
Grp / No. Item
2
Filter 1st Cartridge Scroll Factor 3
3
Filter 1st Cartridge Scroll Factor 4
4
Filter 1st Cartridge Scroll Factor 5
5
Filter 1st Cartridge Scroll Factor 6
6
Filter 1st Cartridge Scroll Factor 7
7
Filter 1st Cartridge Scroll Factor 8
8
Filter 1st Cartridge Scroll Factor 9
9
Filter 1st Cartridge Scroll Factor 10
10
Filter 2nd Cartridge Scroll Factor 1
11
Filter 2nd Cartridge Scroll Factor 2
12
Filter 2nd Cartridge Scroll Factor 3
13
Filter 2nd Cartridge Scroll Factor 4
14
Filter 2nd Cartridge Scroll Factor 5
15
Filter 2nd Cartridge Scroll Factor 6
16
Filter 2nd Cartridge Scroll Factor 7
17
Filter 2nd Cartridge Scroll Factor 8
18
Filter 2nd Cartridge Scroll Factor 9
Filter 2nd Cartridge Scroll Factor
19
10
20
Filter 3rd Cartridge Scroll Factor 1
21
Filter 3rd Cartridge Scroll Factor 2
22
Filter 3rd Cartridge Scroll Factor 3
23
Filter 3rd Cartridge Scroll Factor 4
24
Filter 3rd Cartridge Scroll Factor 5
25
Filter 3rd Cartridge Scroll Factor 6
26
Filter 3rd Cartridge Scroll Factor 7
27
Filter 3rd Cartridge Scroll Factor 8
28
Filter 3rd Cartridge Scroll Factor 9
Filter 3rd Cartridge Scroll Factor
29
10
249
Pressure Sensor
0
Pressure Monitor
1
Pressure Moniture
2
Press Offset
3
Press Calib Effective Diff
4
Press Sensor Calibration Log
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
1
Fan 1 Max Adjust (DAC)
2
Fan 2 Min Adjust (DAC)
3
Fan 2 Max Adjust (DAC)
4
Fan 3 Min Adjust (DAC)
5
Fan 3 Max Adjust (DAC)
6
Fan 4 Min Adjust (DAC)
7
Fan 4 Max Adjust (DAC)
8
Fan 5 Min Adjust (DAC)
9
Fan 5 Max Adjust (DAC)
10
Fan 6 Min Adjust (DAC)
11
Fan 6 Max Adjust (DAC)
12
Fan 7 Min Adjust (DAC)
13
Fan 7 Max Adjust (DAC)
252
Fan Option
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3 Manual Voltage
6
Fan4 Manual Voltage
7
Fan5 Manual Voltage
8
Fan6 Manual Voltage
9
Fan7 Manual Voltage
10
Angle Data A
11
Angle Data B
12
Press Data
Function
1st Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
2nd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
Pressure Value (Original) [ADC]
Pressure Value (Compensated)[ADC]
Offset Value
Effective Range of Calibration
Calibration LOg
0: Excuted and Adquate Offset Value
10:Out of Range (Mini)
20: Out of Range (Max)
99: Not executed
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Angle Data A (Read only)
Angle Data B (Read only)
Air Pressure Data (Read only)
Range
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
-1023 - 1023
0 - 1023
-
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-6
0-1
0-255
0-255
0-255
0-255
0-255
0-255
0-255
-
-
-
-54-
Initial
Note
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
-
-
0
1023
99
* Fan voltage adj.
84
237
83
240
40
244
40
230
41
232
43
233
39
229
0
0
100
100
100
100
100
100
100
-
-
-