Electrical Adjustment
Grp / No. Item
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
8
Enable Close Cmd
9
Speed Control
240
Flow Calibration
0
Flow Calibration Exe
1
Flow Calibration Error Log
2
Clog Check Enable
3
Air Inlet Check Enable
4
Time Limit Auto Scroll Enble
5
Clog Auto Cooling Enable
6
Scroll Fail Auto Cooling Enable
241
Flow Ideal Data
0
Flow Ideal Data 1
1
Flow Ideal Data 2
2
Flow Ideal Data 3
3
Flow Ideal Data 4
4
Flow Ideal Data 5
5
Flow Ideal Data 6
6
Flow Ideal Data 7
7
Flow Ideal Data 8
242
Flow Calib. Fan Volt
0
Flow Calib Fan Volt 1
1
Flow Calib Fan Volt 2
2
Flow Calib Fan Volt 3
3
Flow Calib Fan Volt 4
4
Flow Calib Fan Volt 5
5
Flow Calib Fan Volt 6
6
Flow Calib Fan Volt 7
7
Flow Calib Fan Volt 8
243
Flow Calib Effective Difference
0
Flow Calib Effective Diff 1
1
Flow Calib Effective Diff 2
2
Flow Calib Effective Diff 3
3
Flow Calib Effective Diff 4
4
Flow Calib Effective Diff 5
5
Flow Calib Effective Diff 6
6
Flow Calib Effective Diff 7
7
Flow Calib Effective Diff 8
244
Flow Clog Threshold
0
Flow Clog Threshold 1
Function
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Shutter Close Command 0: Disable, 1: Enable
Shutter Speed
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
Air inlet Error Detection by Wind Sensor (0: Disable, 1: Enable)
Auto Scroll (0: Disable, 1: Enable)
Auto Cooling at Clog (0: Disable, 1: Enable)
Auto Cooling at Scroll Error (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
(Not Memorized)
Flow Sensor Calibration Fan Voltage No.1 [x10 V]
Flow Sensor Calibration Fan Voltage No.2 [x10 V]
Flow Sensor Calibration Fan Voltage No.3 [x10 V]
Flow Sensor Calibration Fan Voltage No.4 [x10 V]
Flow Sensor Calibration Fan Voltage No.5 [x10 V]
Flow Sensor Calibration Fan Voltage No.6 [x10 V]
Flow Sensor Calibration Fan Voltage No.7 [x10 V]
Flow Sensor Calibration Fan Voltage No.8 [x10 V]
(Not Memorized)
Flow Sensor Calibration Range Diff No.1 [ADC]
Flow Sensor Calibration Range Diff No.2 [ADC]
Flow Sensor Calibration Range Diff No.3 [ADC]
Flow Sensor Calibration Range Diff No.4 [ADC]
Flow Sensor Calibration Range Diff No.5 [ADC]
Flow Sensor Calibration Range Diff No.6 [ADC]
Flow Sensor Calibration Range Diff No.7 [ADC]
Flow Sensor Calibration Range Diff No.8 [ADC]
(Not Memorized )
Flow Sensor Clogged Threshold No.1[ADC]
Range
-
0 - 15
0 - 15
-
0 - 32767
:
0 - 32767
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 1
0 - 255
0 - 1
-
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
-5-
Initial
Note
-
15
0
-
0
:
0
0
Initial: 1 / Shipping: 0
7000
15000
10
0
0
50
1
0
* Wind sensor calibra-
0
tion.
255
Initial: 0 / Shipping: 1
Initial: 0 / Shipping: 1
1
1
1
263
263
308
328
346
361
371
383
42
50
60
75
90
105
120
138
300
300
300
300
300
300
300
300
60