Mechanical Disassembly
4. Shutter, Net Joint and Sensor C board removal
1. Loosen 1 screw-A and pull the shutter assy upward.
. Remove 1 screw-B (T3x6) to take the Sensor C board off.
3. Remove 1 screw-C (T3x8) to take the Lamp Cover Switch (SW901) off.
4. Remove  screws-D (T3x14) to take the Wind Sensor (S901) off.
5. Remove  screws-E (M5x10) to take the Terminal Cover off, and remove
1 screw-F (M4x8) and 1 screw-G (M3x8) and then pull the Net Joint board
assy upward.
Shutter assy
Lamp cover switch
(SW901)
5. Lamp, Lamp Cover and IC Connect board removal
1. Loosen 3 screws-A and pull the Lamp assy upward.
. Remove 4 screws-B (T3x8) to take the Lamp house holder upward off.
3. Remove  screws-C (T3x8) to take the ID Connect board.
Lamp assy
c
c
ID Connect
board
t3x8
A
B
c
A
A
A
B
B
B
B
Sensor C board
Wind sensor (S901)
d
-1-
G
F
Net Joint board
assy
Terminal cover
e