7-1. Lens Shift assy removel
1. Remove 4 screws-A (M3x8) to take the Lens Shift assy off.
. Remove 4 screws-B (M3x14) to take the Lens Mount off.
8. Power Box and Thermal SW (SW902) removal
1. Remove  screws-A (M3x8),  screws-B (T3x8) and 1 screw-C (M4x8) and
then remove the Power Box assy.
. Remove 1 screw-D (T3x8) to take the Trigger Box off.
3. Remove 1 screw-E (T3x8) and pull the SW90 upward off from the groove.
Lens mount
B
B
B
SW90
Lens shift assy
A
A
A
Thermal switch
e
(SW90)
Trigger box
-3-
Optical unit assy
A
B
B
A
A
d
Power box assy
c