Section 5 − Installation; Selecting A Location; Connecting Gas/Air Supply; Connecting Work Clamp - Hobart AirForce 700i Owner's Manual

Welding system & torch
Hide thumbs Also See for AirForce 700i:
Table of Contents

Advertisement

5-1. Selecting A Location

!
Do not move or operate unit
where it could tip.

5-2. Connecting Gas/Air Supply

Tools Needed:
9/16 in.

5-3. Connecting Work Clamp

2
OM-244 013 Page 14
.
A complete Parts List is available at www.HobartWelders.com
SECTION 5 − INSTALLATION
18 in.
(460 mm)
1
3
1
!
18 in.
(460 mm)
.
1
2
3
Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.
2
From
Gas/Air
Supply
.
1
2
Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
loc_2 3/96 - Ref. 244 405-A
Use only clean, dry air with 90
to 120 psi (621 to 827 kPa)
pressure.
Gas/Air Inlet Opening
Hose
Teflon Tape
Ref. 244 423-A
Do not connect work clamp to
the portion of the workpiece
that will fall when cut.
Work Clamp
Workpiece
Ref 803 915-A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp-70 torchHp-70

Table of Contents