Code Alarm CA 1550 Owner's Manual page 20

2 way lcd vehicle security and keyless entry system professional series
Hide thumbs Also See for CA 1550:
Table of Contents

Advertisement

1
2
5 Pin Main Harness
WHITE/RED
WHITE
PARKING LIGHT INPUT
PARKING LIGHT OUTPUT
Locate the parking light output wire at the vehicle's light switch.
Verification: This wire registers positive voltage when the parking lights are
turned on.
Positive switching Parking Lights:
Connect the WHITE/RED wire to a 15 Amp max fused battery source.
Connect the WHITE wire to the parking light output wire.
Negative switching Parking Lights:
Connect the WHITE/RED wire to a good chassis ground.
Connect the WHITE wire to the parking light output wire.
3
BLACK
GROUND
Connect the BLACK wire to a solid chassis ground point using a ring terminal and
self tapping screw (not supplied). Scrape away paint from the grounding point to
ensure a good connection. The recommended grounding point is a metal surface
in the driver's side kick panel area.
NOTE: Do not ground the BLACK wire with any other vehicle components.
4
BROWN
SIREN OUTPUT (
+ )
Locate a suitable mounting location in the engine compartment for the siren, away
from moving parts.
With the bell of the siren aiming downwards, secure the siren in place using self
tapping screws, being careful not do drill into any hoses, wiring or components.
Connect the BLACK siren wire to a chassis ground using a ring terminal and self
tapping screw (not supplied).
Route the BROWN siren output wire from the control module through the firewall
and connect to the RED wire on the siren.
NOTE: Be sure to loom the siren wires, and seal the grommet.
2009 Audiovox Electronics Corporation. All rights reserved.
5

Advertisement

Table of Contents
loading

Table of Contents