Use pipe that is the same size as the air tank outlet. Piping that is too
small will restrict the flow of air.
If piping is over 100 feet long, use the next larger size.
Bury underground lines below the frost line and avoid pockets where
condensation can gather and freeze. Apply pressure before underground
lines are covered to make sure all pipe joints are free of leaks.
A flexible coupling is recommended to be installed between the air
discharge outlet and main air distribution line to allow for vibration.
A separate regulator is recommended to control the air pressure. Air
pressure from the tank is usually to high for individual air driven tools.
FEEDER LINES SLOPE
AIR FLOW
MAIN DISTRIBUTION AIR LINES
Slope pipe in direction of air flow.
Water condensate flows along
bottom of pipe to drain legs,
preventing it from entering feeder
lines.
LUBRICATOR
MOISTURE
SEPARATOR
AND TRAP
DIRT
LEG
TYPICAL COMPRESSED

AIR DISTRIBUTION SYSTEM

WITH AIR FLOW
REGULATOR
DRAIN
TRAP
AIR FLOW
AIR USAGE
LINES
DIRT
LEG
FILTER
FLEXIBLE
COUPLING
AIR DISCHARGE
VALVE
DRAIN COCK
VALVE
11- ENG
DRAIN
LEGS
DRAIN
TRAPS
REGULATOR
LUBRICATOR
AIR
COMPRESSOR
D24225