SECTION 10
SLIDEOUT SYSTEMS
After the slideout is
extended, verify that
the corners of the
black rubber seal are
set up correctly. The
corners of this seal
are cut at a 45°
angle. The top of the
seal must overlap
the side of the seal
to
avoid
the
possibility of water penetration.
Retracting slideout room
Press the IN section of the slideout control
switch and hold it until the motor stops.
Operating the switch after the room is fully
retracted will damage the switch and motor.
Maintenance
Do not work on your system unless the 12-
volt
DC
(auxiliary
supplied)
and
120-volt
systems (shore line power cord) have been
disconnected.
Your slideout system has been designed to
require very little maintenance. To ensure a
long life of your slideout system, read,
understand
and
follow
instructions. This system contains a pre-lubed
bearing that is lubricated when the room is
moved in and out. Do not spray oil or grease
on the rails while the room is extended.
T
ROUBLESHOOTING
If the slideout does not move when the
slideout switch is depressed, follow these
steps.
Check the auxiliary battery (customer
supplied) for a full charge and good wire
connections.
Check the 12-volt fuse or circuit breaker.
Check for loose connections at the
slideout motor.
If the slideout still will not operate, follow
these steps.
74
Fig. 10.4 Exterior
slideout room corner
battery,
customer
AC
electrical
these
simple
T
S
HE

LIDEOUT

If the slideout is extended, refer to the
following section on overriding the specific
slideout system installed on your RV.
If the slideout is retracted, leave it in that
position.
Contact your dealer or Jayco Customer
Service for repair assistance.
If the slideout extends crooked or only one
side moves, follow these steps.
Follow steps on overriding the specific
slideout system installed on your RV.
You may need to push the side that is not
sliding to get it to retract all the way.
Contact your dealer or Jayco Customer
Service for repair assistance.
Power Gear slideout override
Do not work on your system unless the
battery is disconnected. Failure to comply
could result in death or serious injury.
Locate and remove the access panel for the
slideout motor.
Fig. 10.5 Main room slideout motor
1. From the rear of the motor, rotate the
brake release lever counter-clockwise 1/8
turn. This will release the brake that locks
the slideout in place.
2. Disconnect one slideout motor wire near
the motor.
3. The slideout is now free to move. Locate
the access panel either at the front or rear
of the slideout rail. Remove the access
panel for the manual slideout shaft.
4. Use a 3/4 socket and ratchet on the hex
head located on either end of the drive

Hide quick links: