General Troubleshooting

Page 20 of 24
Symptom
Excessive load on the circuit
Circuit breaker
or fuse keeps
blowing
Short circuit along the power
lines
No energy on power outlet
Loose or damaged power cord
Product does
Blown fuse
not power up
Internal problem
Wrong starting address on the
fixture
Wrong DMX personality on the
fixture
Fixture does not
respond to DMX
Wrong polarity setting on the
DMX controller
Loose or damaged DMX cable
Internal problem
Signal cables are not DMX
compatible
Interference with AC or radio
signals
DMX cable too long
Intermittent DMX
Problems
Too many fixtures connected
Terminator not connected
If you still experience problems after trying the above solutions, contact CHAUVET®
Technical Support.
Possible Cause
Scorpion™ RVM/RGY/GVC User Manual (Rev. 01e)
Possible Action
Make sure that the total load
does not exceed 80% of the
breaker or fuse nominal current
Check the power lines and
power cords
Check power outlet
Change to another outlet
Check the power cord
Replace blown fuse with a
good one of the same type and
rating
Send product for repair
Set the correct starting address
on the fixture
Use the right fader(s) on the
controller
Set the correct DMX personality
on fixture
Assign the faders accordingly
Change the signal polarity on
the controller
Check the DMX cable before
the faulty unit
Send product for repair
Replace non DMX cables with
true DMX cables
Keep DMX cables away from
AC wires or radio equipment
Install an optically coupled
DMX amplifier right before the
fixture with intermittent
problems
Install an optically coupled
DMX amplifier after unit #32
Install a terminator, as indicated
in "DMX Primer".