Control Panel; Lcd Display; Master Dial; Top Temp - GBC 2064WF-1 Installation And Operating Manual

Wide format laminator
Table of Contents

Advertisement

GBC 2064WF-1
CONTROL GUIDE
1
Set Temp.
Current Temp.
TOP: 150*F
BOT: 150*F
MODE: FWRD
SPEED: 08ft
3
2

Top Temp

4

MASTER DIAL

Bottom Temp

5

Speed

9
10

Stop

Rear

FIGURE 1
A. Power ON/OFF (I/O):
Located at the back left of the machine applies power to
the laminator. The control panel display will illuminate
when position marked "I" is pushed. The Off position,
marked "O" removes power from the laminator.
B. Control Panel (FIGURE 1)
1. Main display Read out:
Illuminates when the laminator is plugged in and
POWER ON/OFF is in the on, (I), position.
Displays settings for the top heater, bottom
heater, speed, job mode, and ready/wait.
TOP: Refers to the Top Main Rollers
temperatures setting and Current Temperature.
BOT: Refers to the Bottom Main Rollers
temperatures setting and Current Temperature.
MODE: Displays the Direction the rollers are set
to... In FIGURE 5, the MODE is shown in the
"FWRD" position.
SPEED: Speed is displayed in Feet per Minute or
ft/mn. FIGURE 5 Displays the Speed set at 8ft.
© 2009 General Binding Corporation an ACCO Brands CO.
TOP: 140*F
TOP: 145*F
GAP: 000%
PRS: 030%
8

Reset

7
Meas.
6

Cooling

11

Forward

GAP: As the rollers are lifted, the GAP is
measured digitally. The value is shown as a
percentage. No GAP equals 000%, completely in
the up positions equals 100%.
PRS: PRS refers to the amount of downward
pressure being applied to the Main Rollers. The
value is shown as a percentage.
shows the PRS is set for 30%. No Pressure will
equal 000%, maximum pressure will read 100%.
2. Master Dial:
Increases (+) or decreases (-) the numeric
value for the selected setting when turned.
3. Top Temp:
When
pressed,
decreasing of the top set temperature by
turning the MASTER DIAL and is indicated
on the control panel display. Range is 32°F-
300°F.
4. Bottom Temp:
When
pressed,
decreasing of the bottom set temperature by
turning the MASTER DIAL and is indicated
on the control panel display. Range is 32°F-
300°F.
5. Speed:
When
pressed,
decreasing of speed by turning the MASTER
DIAL and is indicated on the control panel
display. Range is 1-15.
6. Cooling:
When pressed, turns on the cooling fans.
When pressed again, turns off the cooling fans.

7. Measure:

When pressed, allows the operator to view the
amount of linear feet that the machine has run.
8. Reset:
When pressed, permits the operator to rest the
linear feet counter.
9. Stop:
When pressed, the rollers will stop rotating.
10. Rear:
When pressed, the rollers will allow the
operator to run the machine in reverse or the
rear.
11. Forward:
When pressed, the rollers will allow the
operator to run the machine in forward mode
or from the front.
Operation Manual
FIGURE 5
permits
increasing
or
permits
increasing
or
permits
increasing
or
Page 8