Heating / Cooling Application Wiring Diagram - Carrier 58RAV 170 Series Installation, Start-Up, And Operating Instructions Manual

Downflow/horizontal induced-combustion furnaces sizes 050-135, series 170 and 180
Table of Contents

Advertisement

115-VAC (L1)
POWER SUPPLY
HOT SURFACE
IGNITOR CONNECTOR
WIRE
THREE-WIRE
HEATING-
ONLY
BLK
BLK
WHT
WHT
GND
GND
AUXILIARY
115-V
J-BOX
FIELD-SUPPLIED
CONTROL
DISCONNECT
FURNACE
Fig. 15—Heating and Cooling Application Wiring Diagram
TEST/TWIN
SEC-1
3-AMP FUSE
COOL
HEAT
115-VAC (L2) NEUTRAL
CONNECTION
INDUCER MOTOR
CONNECTOR
Fig. 14—Furnace Control
NOTE 2
W
C
R
FIVE
W
R
G
C
NOTE 1
Y
BOX
24-V
TERMINAL
BLOCK
NOTES:
24-V THERMOSTAT
TERMINALS
HUMIDIFIER TERMINAL
(24-VAC 0.5 AMP MAX)
HUM
LED OPERATION &
DIAGNOSTIC LIGHT
HARNESS CONNECTOR
24-V TRANSFORMER SEC-2
SPARE-1
BLOWER SPEED
SELECTION TERMINALS
SPARE-2
EAC-1
EAC-ELECTRONIC AIR CLEANER
TERMINALS (115-VAC 1.0 AMP MAX)
EAC-2
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
THERMOSTAT
G
Y
TERMINALS
CONDENSING
UNIT
TWO
WIRE
1.
Connect Y-terminal as shown for proper operation.
2.
Some thermostats require a "C" terminal connection as shown.
3.
If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
12
FIELD-SUPPLIED
DISCONNECT
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
GND
A99255
A98209