Summary of Contents for Carrier 58PAV

  • Page 1 Digitally signed GoGeisel .com eisel. cn=GoG eisel.com , c=US Date: 2003.01. Signa.. ture 18:06:36 Verifie -05'00'...
  • Page 2: Welcome To Today's Generation Of Comfort

    Years went into the develop- ment of your new furnace. Take a little time now to assure its most efficient operation for years to come. MODEL 58PAV MODEL 58RAV UPFLOW FURNACE DOWNFLOW/HORIZONTAL FURNACE...
  • Page 3 Upflow furnace components Relief Box Rating Plate Gas Valve Control Knob (On/Off) Gas Valve Gas Burner Flame Sensor Air Filter Retainer Air Filter Blower and Blower Motor Draft Safeguard Tube and Switch Gas Manifold Manual Reset Limit Switch Hot Surface Ignitor Blower Door Safety Switch Downflow/horizontal furnace components Manual-Reset Auxiliary Limit Switch...
  • Page 4: Important Facts

    Important facts trained and qualified personnel should install, repair, or service heating equipment. Your furnace must have adequate airflow for efficient Untrained personnel can perform basic maintenance func- combustion and safe ventilation. Do not enclose it in an tions such as cleaning and replacing air filters. All other airtight room or “seal”...
  • Page 5: Steps For Starting Your Furnace

    • Check Air Filter: Before attempting to start your fur- nace, be sure the furnace filter is clean and in place. (See the maintenance section of this manual.) Then proceed as follows: Steps for starting your furnace 1. Set your room thermostat to the lowest temperature setting.
  • Page 6: Shutting Down Your Furnace

    switched on automatically. When the room temperature WARNING reaches the degree selected on the thermostat, the furnace Turn off electrical power supply to your furnace will be automatically switched off. before removing the access doors to service or Some thermostats have a “fan” switch with 2 selections: perform maintenance.
  • Page 7: Combustion Area And Vent System

    7. Wash the filter (if dirty) in a sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water through the filter in the opposite direction of airflow through the cross-mesh binding side.
  • Page 8 pushing the button located on top of the switch (see page 3 for switch location). If the switch trips a second time, turn off the furnace and call for service. • Downflow/Horizontal Only—Check the manual-reset auxiliary limit switch located on the blower housing. If the blower motor fails, this switch will shut off the furnace.
  • Page 9 INSTALLATION DATA SPLIT-SYSTEM Date Installed Product No. Dealer Name Model No. Address Serial No. City State INDOOR COIL: Telephone Product No. Model No. FURNACE Serial No. Product No. Model No. Serial No.
  • Page 10 Have available the Model No., Series Letter & Serial No. of your equipment to insure correct replacement part. Carrier Corporation Syracuse, New York 13221 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations . Copyright 1992 Carrier Corporation Form: OM58-60 Replaces: OM58-52 Printed in the U.S.A.