Electrical Connections; 115-V Wiring; Horizontal Crawlspace Installation On Hanger Rods; Horizontal Filter Arrangement - Carrier 58RAV 170 Series Installation, Start-Up, And Operating Instructions Manual

Downflow/horizontal induced-combustion furnaces sizes 050-135, series 170 and 180
Table of Contents

Advertisement

ANGLE
IRON OR
EQUIVALENT
(B)
(A)
ROD LOCATION
USING DIMPLE
LOCATORS
(SEE DIMENSIONAL
DWG FOR
LOCATIONS)
(A) PREFERRED ROD LOCATION
(B) ALTERNATE ROD LOCATION
Step 10—Electrical Connections

115-V WIRING

Refer to the unit rating plate or Table 6 for equipment electrical
requirements. The control system requires an earth ground for
proper operation.
Do not connect aluminum wire between disconnect switch
and furnace. Use only copper wire.
Make all electrical connections in accordance with the current
edition of the National Electrical Code (NEC) ANSI/NFPA
70-1999, and any local codes or ordinances that might apply. For
Canadian installations, all electrical connections must be made in
accordance with Canadian Electrical Code CSA C22.1, or authori-
ties having jurisdiction.
NOTE: Proper polarity must be maintained for 115-v wiring. If
polarity is incorrect, control center status code indicator light will
flash rapidly and furnace will not operate.
3
/
-IN. HEX NUT
8
& WASHER (4)
REQD PER ROD
Fig. 10—Horizontal Crawlspace Installation on Hanger Rods
(B)
(A)
(A)
(B)
NOTES:
1. A 1 In. clearance minimum between top of
furnace and combustible material.
2. The entire length of furnace must be
supported when furnace is used in horizontal
position.
AIRFLOW
12"
Fig. 11—Horizontal Filter Arrangement
→Table 4—Filter Retainer (In.)
FURNACE
CASING WIDTH
14-3/16
17-1/2
21
24-1/2
10
3
-IN. ROD
8
(A)
(B)
D
4"
FIELD-SUPPLIED
FILTER RETAINERS
FILTER SIZE
AND QUANTITY
(2) 16 X 20 X 1
(2) 16 X 20 X 1
(2) 16 X 20 X 1
(2) 16 X 20 X 1
A96633
A82173
D
14-3/8
13-3/8
11-5/8
10-1/4