Automatic Shut Off System; Emergency Depressurization - Central Pneumatic 61693 Owner's Manual & Safety Instructions

21gal cast iron vertical air compressor
Table of Contents

Advertisement

Emergency Depressurization

If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF.
Then, pull on the ring on the Safety Valve to quickly release stored air pressure.

Automatic Shut off System

1. If the Air Compressor automatically shuts off
before reaching its normal cutoff pressure:
a. Shut off all tools.
b. Wait until the Air Compressor
cools down (about 10 minutes).
c. If the unit does not start up again on
its own, press the Reset Button to start
the compressor. See Figure I.
d. Resume operation.
Reset
Button
Figure I
ITEM 61693
For technical questions, please call 1-888-866-5797.
2. Possible causes of repeated automatic
shut off of the Air Compressor are:
Using an extension cord that is too
long or too small a gauge.
An air leak or open hose causing the Air
Compressor to cycle too often and build up heat.
3. Correct any issues before further use to
avoid damage to the compressor.