Emergency Depressurization; Automatic Shut Off System - Central Pneumatic 67708 Set Up And Operating Instructions Manual

2-1/2 hp 10 gallon 125 psi air compressor
Table of Contents

Advertisement

13. After the job is complete, turn the Power
Switch OFF.
14. Unplug the Air Compressor.
15. Close the in-line Shutoff Valve.
16. Bleed air from the tool then disconnect
the tool.
17. Turn the Drain Valve (66), at the bottom
of the Tank, two turns clockwise to
release any built-up moisture and the
internal tank pressure. Close the valve
after moisture has drained out. Do not
remove the Drain Valve.
18. Clean, then store the Air Compressor
indoors.

emergency depressurization

If it is necessary to quickly depressurize
the Compressor, turn the Power Switch
OFF. Then, pull on the ring on the Safety
Valve (73) to quickly release stored air
pressure.

automatic Shut off System

Figure 4
1.
If the Compressor automatically shuts
off:
a. Shut off all tools.
Page 12
Reset Button
For technical questions, please call 1-800-444-3353.
b. Wait until the Compressor cools down
(about 10 minutes);
c. If the unit does not start up again on it's
own, press the Reset Button to start the
compressor;
d. Resume operation.
2.
Possible causes of repeated automatic
shut off of the compressor are:
a. Using an extension cord that is too long
or narrow;
b. An air leak or open hose causing the
compressor to cycle too often and build
up heat.
3.
Correct any issues before further use to
avoid damage to the compressor.
SKU 67708