What to Expect with
Your Installation
7 feet
Preparation
Blades
Switch Housing
12
M3521-01 • 05/14/14 • © Hunter Fan Company
Tools Needed
30 inches
2
Ladder
3
Downrod
6
7
Light Kit
13
14
1
www.HunterFan.com
Mounting Options
Ceiling Bracket
4
Wiring
10
Operation, Maintenance
& Cleaning
Troubleshooting
?
?
16
1.888.830.1326
5
Canopy
11
?
18

Advertisement

Table of Contents
loading

Summary of Contents for Hunter ceiling fan

  • Page 1 What to Expect with Your Installation Tools Needed Mounting Options Ceiling Bracket your new Hunter® ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation 30 inches manual contains complete...
  • Page 2: What To Expect With Your Installation

    Assess ceiling angle Select a downrod length harmful interference to radio communications. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 3: Tools Needed

    Tools Needed www.HunterFan.com 1.888.830.1326 Pliers Wire Strippers Screwdrivers Ladder Power Drill 9/64” Drill Bit (optional) (optional) If mounting to a support structure, you will also need these tools. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 4: Mounting Options

    You need BOTH You need ONLY a Longer a Longer Downrod & Downrod an Angled Mounting Kit *most common M3521-01 • 05/14/14 • © Hunter Fan Company M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 5: Ceiling Bracket

    To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet Refer to warning w.1 on pg. 2 box associated with the wall switch location. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 6 Remove the shipping blocks from the motor. Discard the screws. Note: Some fans will have a shipping ring instead of shipping blocks. Please remove the ring and discard the screws. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 7 If you need a different downrod length follow these steps: Steps 1-5 to remove standard downrod pipe Longer Downrod for angled ceilings or ceilings 10’ or higher Steps 6-10 to reassemble with new pipe M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 8 4-5 full turns) until it stops. with pliers. DO NOT can be inserted. from the top of the downrod. HAND TIGHTEN. 8” 3/8” If the setscrew is not tightened securely, the fan may fall. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 9 Put the wires and downrod through the canopy. Let the canopy sit loosely CANOPY OR WIRES. Place the downrod on top of the fan. ball into the slot in the ceiling bracket. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 10 Spread the wires apart, with the grounded wires on one side of Refer to CAUTION c.1 on pg. 2 the outlet box and the ungrounded wires on the other side of the outlet box. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 11 Insert the two canopy screws lifted into place, the canopy fits into the screw holes are aligned. found in the hardware bag. the hanging bracket as shown. Note: Fan style may vary. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 12 Your blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. For cleaning the fan, use soft brushes or cloths to prevent scratching. Cleaning agents may damage the finishes. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 13: Switch Housing

    Make sure the upper switch housing is securely attached to the mounting plate. Failure to properly secure all 3 assembly screws could result in the switch housing fixture falling. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 14: Light Kit

    Make sure the lower switch housing is securely attached to Note: Globe style and number of the upper switch housing. Failure to properly secure all three lights may vary. assembly screws could result in the light fixture falling. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 15: Operation Instructions

    Note: Globe style and number of Note: In compliance with US federal energy regulations, this ceiling fan lights may vary. contains a device that restricts its light output. Exceeding the wattage limit marked on the MAX wattage sticker affixed to the light socket(s) may result in fire hazard or improper operation.
  • Page 16 Note: For rocker-style cover plates, fan, wait 1 minute then try again. If break off the tabs by pushing outward. Turn Power using the transmitter with multiple fans, repeat this process for each fan. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 17 For cleaning the fan, use soft brushes or the reverse switch to the opposite cloths to prevent scratching. Cleaning position. You will need to remove the products may damage the finishes. light kit glass to do so. M3521-01 • 05/14/14 • © Hunter Fan Company...
  • Page 18: Troubleshooting

    Transmitter only works when and click “How do I properly install held at close range multiple remote-controlled fans?” • Install a fresh battery. for information on how to correct this issue. M3521-01 • 05/14/14 • © Hunter Fan Company...

This manual is also suitable for:

Ceiling fan

Table of Contents