Miele KM 6388 Operating And Installation Instructions page 53

Ceramic hobs with induction
Table of Contents

Advertisement

Minimum safety distances un‐
derneath the hob
To ensure sufficient ventilation to the
hob, a certain gap must be left between
the underside of the hob and any oven,
interim shelf or drawer.
The minimum gap between the under‐
side of the hob and
– the top of an oven is 15 mm.
– the top of an interim shelf is 15 mm.
– the base of a drawer is 75 mm.
Safety distances
Interim shelf
It is not necessary to fit an interim shelf
underneath the hob but one may be fit‐
ted if you wish.
Leave a gap of 10 mm at the back of
the shelf to accommodate the cable.
We recommend a gap at the front of the
shelf of 20 mm to ensure good ventila‐
tion.
53