Manufactured Home Requirements; Location - Superior SLDVT-40NM Installation Instructions Manual

Sldvt direct-vent gas fireplaces
Table of Contents

Advertisement

MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed in
an aftermarket permanently located,
manufactured home and must be installed
in accordance with the manufacturer's
instructions.
Cet appareil peut être installé cómme
du matéri-el d'origine dans une maison
préfabriquée (É.U. seulement) ou
mobile et doit être installé selon les
instructions du fabricant.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Cet appareil doit être utilisé uniquement
avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil ne peut être
converti à d'autres gaz, sauf si une
trousse de conversion est utilisée.
CAUTION
Ensure that the cross members
are not cut or weakened during
installation. The structural
integrity of the manufactured
home floor, wall, and ceiling /
roof must be maintained.
CAUTION
This appliance must be
grounded to the chassis of
the manufactured home in
accordance with local codes or
in the absence of local codes,
with the National Electrical Code
ANSI / NFPA 70—latest edition or
the Canadian Electrical Code CSA
C22.1—latest edition.
SUPERIOR DIRECT-VENT GAS FIREPLACES • SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS

LOCATION

In selecting the location, the aesthetic and
functional use of the appliance are primary
concerns. However, vent system routing to
the exterior and access to the fuel supply
are also important.
Due to high temperatures, the appliance
should be located out of traffic and away
from furniture and draperies (Figure 3).
En raison des températures élevées,
l'appareil devrait être installé dans
un endroit où il y a peu de circulation
et loin du mobilier et des tentures
(Figure 3).
Figure 3: Typical Locations
APPLICATION
TOP VENT
HORIZONTAL VENT
(Top Vent Application)
The location should also be free of
electrical, plumbing or other heating/air
conditioning ducting.
These direct-vent appliances are uniquely
suited for installations requiring a utility
shelf positioned directly above the fireplace.
Utility shelves like these are commonly
used for locating television sets and
decorative plants.
Be aware that this is a heat producing
appliance. Objects placed above the unit are
exposed to elevated temperatures.
Do not insulate the space between the
appliance and the area above it (Table 8).
DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
RECESSED
INSTALLATION
TOP VENT
APPLICATION
VERTICAL VENT
(Top Vent Application)
The minimum height from the base of the
appliance to the underside of combustible
materials used to construct a utility shelf in
this fashion is shown in Table 8.
The appliance must be mounted on a
fully supported base extending the full
width and depth of the unit. The appliance
may be located on or near conventional
construction materials. However, if
installed on combustible materials, such as
carpeting, vinyl tile or other combustible
material other than wood flooring, the
appliance shall be installed on a metal or
wood panel extending the full width and
depth of the appliance.
NOTE: When the unit is installed with
one side flush with a wall, the wall
on the other side of the unit must
not extend beyond the front edge of
the unit.
5