Optional Blower Kit Wiring; Connecting Gas Line - Superior SLDVT-40NM Installation Instructions Manual

Sldvt direct-vent gas fireplaces
Table of Contents

Advertisement

6. If a wall-mounted ON/OFF control or
thermostat is to be used, mount it in a
convenient location on a wall near the
fireplace.
7. If an optional control is to be used, wire
it in the low voltage circuit as shown in
Figure 27.
NOTE: The supplied 15 ft of
2-conductor wire has one end of
each conductor connected to the gas
valve circuit and the other end of each
conductor placed loose inside the
bottom compartment.
8. After the wiring is complete, replace the
cover plate.
WARNING
Electronic models of these
appliances are equipped with
a three-prong (grounding) plug
utilized in connecting the electronic
components to the junction box
in the lower compartment. This
grounding plug provides protection
against shock hazard and should
be plugged directly into a properly
grounded three-prong receptacle.
DO NOT cut or remove the grounding
prong from the plug.
Wire the [Optional] Blower Kit After
Installation in the Framing
FBK-100, FBK-200, and FBK-300 Kits
An electrical outlet box is provided for the
installation of the FBK-100, FBK-200, and
FBK-300 forced air blower kits. Electrical
power must be provided to the box to
operate the blower. Install the blower kit
according to the installation instructions
provided with the kit.
NOTE: The tab connecting the receptacles of
the outlet box must be broken in FBK-100
and FBK-200 blower kit applications
(Figure 28).
24
SUPERIOR DIRECT-VENT GAS FIREPLACES • SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS
Figure 28: Junction Box Wiring
Plug blower
into this
receptacle
Ground
Connect the Gas Line
All codes require a shut-off valve mounted
in the supply line. Figure 29 illustrates two
methods for connecting the gas supply.
The flex-line method is acceptable in the
U.S., however, Canadian requirements vary
depending on locality. Installation must be
in compliance with local codes.
These appliances are equipped with a
gas flex line for use (where permitted) in
connecting the unit to the gas line. A gas
flex line is provided to aid in attaching the
direct vent appliance to the gas supply. The
gas flex line can only be used where local
codes permit. The flex line is rated for both
natural and propane gas. A manual shut off
valve is also provided with the flex line.
The gas control valve is located in the lower
control compartment (Figure 30).
Remove Control Compartment Door
Open the panel by grasping the control
compartment door on both sides and gently
pulling the top away from the fireplace to
disengage the magnetic fasteners. The door
is hinged at the bottom. If greater access
to the control compartment is required,
slide the door, first to one side and then
the other, so the tabs clear both of the
locating holes.
DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
BLOWER CONTROL CIRCUIT WIRING
120V, 60HZ, 1PH
* Wall-mounted
ON/ OFF Blower
Switch or Variable
Speed Control Switch.
Junction Box
Tab
Broken
Hot
Side of
Red
Black
Receptacle
Neutral
Side of
Receptacle
Tab Intact
Green
Ground
Screw
Field Wired
Blower
Factory Wired
Millivolt and electronic control valves have a
3/8 in. (10 mm) NPT thread inlet port.
Secure all joints tightly using appropriate
tools and sealing compounds (ensure
propane resistant compounds are used
in propane applications). Optionally, seal
around the gas line to prevent cold air
leakage. Gas line holes and other openings
can be caulked or stuffed with unfaced
fiberglass insulation.
All codes require a shut-off valve mounted
in the supply line. The orientation of
the shut-off valve should face the front.
Figure 29 illustrates two methods for
connecting the gas supply. A sediment
trap is recommended to prevent moisture
and debris in the gas line from damaging
the valve.
WARNING
Never use an open flame to check
for leaks.