17-Class Unit In Single Operation - Mitsubishi Electric MSH09TW Service Manual

Wireless type
Table of Contents

Advertisement

5. 17-class unit in single operation (OUTDOOR UNIT : MXZ30TN MXZ30TN2)
(1) COOL operation
1Data is based on the condition of indoor
humidity 50%
Air flow speed : High
Inverter output frequency : 33Hz
(PSIG)
100
95
90
85
80
75
70
65
65 70 75 80 85 90 95 100 105 110 115
Ambient temperature(°F)
(2) HEAT operation
Data is based on the condition of outdoor
humidity 75%
Set air flow to High speed.
Inverter output frequency is 45Hz.
<How to work fixed-frequency operation>
1.Set emergency switch to COOL or HEAT.The switch is locat-
ed on indoor unit.
2.Press emergency run ON/OFF button.
3.Compressor starts running at 33Hz (COOL) or 45Hz (HEAT).
4.Indoor fan runs at High speed.
5.To cancel this operation,press emergency run ON/OFF button
or any button on remote controller.
7.0
6.0
5.0
4.0
3.0
33Hz
2.0
1.0
(°F)
65 70 75 80 85 90 95 100 105 110 115
9.0
8.0
7.0
6.0
5.0
4.0
15 20 25 30 35 40 45 50 55 60 65 70 75
38
33Hz
Ambient temperature(°F)
45Hz
Outdoor ambient temperature(°F)
86
80
75
70
(°F)
75
70
65