MSH15TN
MSH15TN
INDOOR UNIT
Indoor coil
thermistor
Indoor
RT12
heat
Distributor
exchanger
Room temperature
thermistor
RT11
MSH17TN MSH17TN -
INDOOR UNIT
Indoor coil
thermistor
Indoor
RT12
heat
exchanger
Distributor
Room temperature
thermistor
RT11
-
U1
Refrigerant pipe [5/8
(Option)
(with heat insulator)
Stop valve
(with service
port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [1/4
(Option)
(with heat insulator)
U1
Refrigerant pipe [5/8
(Option)
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [1/4
(Option)
(with heat insulator)
4-way
Muffler
valve
Fusible
plug
Service
port
Accumulator
Muffler
Compressor
Capillary tube CT3
O.D. 0.12 I.D.0.079 23-5/8
Strainer
#100
Check
valve
4-way
valve
Service
Strainer
port
#100
Fusible
plug
Accumulator
Muffler
Compressor
Capillary tube CT3
O.D. 0.12 I.D. 0.079 9-13/16
Strainer
#100
Check
valve
52
MUH15TN
MUH15TN -
MUH15TN -
OUTDOOR UNIT
Service
port
Outdoor
Strainer
heat
#100
Defrost
exchanger
thermistor
RT61
Capillary tube CT1
O.D. 0.12 I.D.
0.055 11-13/16
Capillary tube CT2
O.D. 0.12 I.D.0.079 7-7/8
R.V.
heating ON
cooling OFF
Flow of refrigerant (cooling)
Flow of refrigerant (heating)
MUH17TN MUH17TN -
OUTDOOR UNIT
Muffler
Outdoor
Service
heat
port
exchanger
Defrost
thermistor
(RT61)
Distributor
R.V. coil
heating ON
cooling OFF
Capillary tube CT2
O.D. 0.12 I.D. 0.079 27-9/16
Flow of refrigerant (cooling)
Flow of refrigerant (heating)
Unit:inch
U1
U2
coil
Unit:inch
U1