6-4. STANDARD OPERATION DATA

Model
Item
Capacity
Total
SHF
Input
Indoor unit
Power supply (V, phase, Hz)
Input
Fan motor current
Aux. heater current
Electrical
circuit
Outdoor unit
Power supply (V, phase, Hz)
Input
Comp. current
Fan motor current
Condensing pressure
Suction pressure
Discharge temperature
Refrigerant
Condensing temperature
circuit
Suction temperature
Comp. shell bottom temp
Ref. pipe length
Refrigerant charge (R22)
Intake air temperature
Indoor
unit
Discharge air temperature
Fan speed (High)
Airflow (High)
Intake air temperature
Outdoor
unit
Fan speed
Airflow

POWER SUPPLY

MSH09TW MSH09TW -
•Both wirings can be applied to all MODELS.
INDOOR UNIT 115V 60Hz 1[, 2 wires
OUTDOOR UNIT
Unit
Btu / h
kW
kW
A
A
kW
A
A
PSIG
PSIG
˚F
˚F
˚F
˚F
ft.
˚F
DB
˚F
WB
˚F
DB
˚F
WB
rpm
CFM
˚F
DB
WB
˚F
rpm
CFM
U1
SIGNAL WIRE
2 wires 12V DC
115V
60Hz 1[, 2 wires
MSH09TW MSH09TW -
Cooling
8,800
0.70
MSH09TW MSH09TW -
MUH09TW MUH09TW -
235
70
179
113
52
157
80
67
59
57
950
233(Wet)
95
INDOOR UNIT
115V 60Hz 1[,
Disconnect
2 wires
switch
SIGNAL WIRE
2 wires 12V DC
OUTDOOR UNIT
27
U1
Heating
10,500
0.89
U1
115,1,60
0.035
0.34
U1
115, 1, 60
0.855
6.91
0.59
223
171
110
146
25
2 lb. 3 oz.
100
1,000
297(Dry)
640
985
Control voltage
Power supply voltage to serial
signal circuit is 12V DC.
Peak voltage between
and 3 3 + on in-out terminal
block is 12V DC .
115V
60Hz 1[, 2 wires
60
35
70
60
47
43
1 1 -