Nomenclature; Description; Standard Features/Benefits - York CHAMPION R-410A Technical Manual

Champion r-410a single package gas/electric air cooled air conditioners 2 thru 5 nominal ton
Hide thumbs Also See for CHAMPION R-410A:
Table of Contents

Advertisement

036-21548-001-D-0405

NOMENCLATURE

PRO UCT CATEGORY
= Single Package Air
Conditioner
PRO UCT GENERATION
1 = 1st Generation
PRO UCT I ENTIFIER
NZ = R-410A 12/13 Seer
Gas Heat/Electric

DESCRIPTION

These packaged cooling/heating air conditioners are
designed for outdoor installation. Only utility and duct con-
nections are required at the point of installation.
The gas-fired heaters have aluminized steel tubular heat
exchangers and hot surface to pilot ignition. They are avail-
able in natural gas with field conversion to propane.

STANDARD FEATURES/BENEFITS

OPERATING EFFICIENCY - All units provide high operating
efficiencies and have a minimum AFUE of 80% and SEERS of
12.0 and 13.0. All efficiencies exceed legislated minimum levels.
ON SITE FLEXIBILITY - All model sizes share a common,
compact design cabinet in a single footprint. The installer has
the flexibility of setting one curb and placing the proper ton-
nage unit on that curb after the internal load has been deter-
mined. Field convertible duct connections from side shot to
down shot allows the installer to have greater flexibility with
less inventory.
LOWER INSTALLATION COST - Installation time and costs
are reduced by easy power and control wiring connections.
The small base dimension means less space is required on
the ground or roof, plus, the installer can fit this unit between
the wheel wells of full size pick-up truck. All models are well
under 500 pounds.
All units are completely wired, charged with R-410A and
tested prior to shipment. Unique test stations using a new
state of the art computerized process system are used to
insure product quality. Refrigerant charge and component
part numbers are verified via computers at assembly. Vital
Unitary Products Group
1 N Z
0
3
6
N
NOMINAL COOLING
CAPACITY (MBH)
INSTALLE GAS HEAT
024 = 24,000 BTUH
N = Natural Gas Heat Installed
030 = 30,000 BTUH
036 = 36,000 BTUH
042 = 42,000 BTUH
048 = 48,000 BTUH
060 = 60,000 BTUH
run test statistics such as system pressure, motor currents,
air velocity and temperature, unit vibration, and gas system
safeties are monitored and recorded by the system to insure
unit performance.
Equal size, side supply and return duct connections allows
easy hook-up of ducts to match low crawl spaces without
transition pieces.
UTILITY CONNECTIONS MADE EASY - Gas and electric
utility knockouts are provided through the bottom as well as
the side of the unit. Utility connections can be made quickly
and with a minimum amount of field labor. A field supplied
and field installed electrical disconnect switch must be
installed.
CONVERTIBLE AIRFLOW DESIGN - The bottom duct open-
ings are covered when they leave the factory ready to be
used for a side supply / side return application. If a bottom
supply / bottom return application is desired, you simply
remove the two panels from the bottom of the unit and place
them in the side supply / side return duct openings. No panel
cutting is required and no accessory panel is necessary.
Convertible airflow design allows maximum field flexibility and
minimum inventory.
CONDENSATE PAN - A non-corrosive, long-lasting, water-
tight pan is positioned below the evaporator coil to collect and
drain all condensate. Less collection of stagnate condensate
will build-up. The condensate pan conforms to ASHRAE 62-
89 standards (Ventilation for Acceptable Indoor Air Quality).
CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI cop-
per connection is more durable over time. The connection is
rigidly mounted to assure proper fit and leak tight seal.
0
3
6
0 6
NOMINAL GAS HEATING
FACTORY
VOLTAGE CO E
06 = 208/230-1-60
25 = 208/230-3-60
46 = 460-3-60
OUTPUT CAPACITY
036 = 36,000 BTUH
056 = 56,000 BTUH
072 = 72,000 BTUH
065 = 65,000 BTUH
090 = 90,000 BTUH
110 = 110,000 BTUH